Chinese Medical Sciences Journal ›› 2016, Vol. 31 ›› Issue (2): 83-88.doi: 10.1016/S1001-9294(16)30030-X

• • 上一篇    下一篇

Effect of Point-of-care Hemoglobin/Hematocrit Devices and Autologous Blood Salvage on Reduction of Perioperative Allogeneic Blood Transfusion

Wei-yun Chen, Xue-rong Yu*, Jiao Zhang, Qing Yuan, Yu-guang Huang   

  1. Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
  • 收稿日期:2015-10-05 出版日期:2016-06-20 发布日期:2016-06-20

Effect of Point-of-care Hemoglobin/Hematocrit Devices and Autologous Blood Salvage on Reduction of Perioperative Allogeneic Blood Transfusion

Wei-yun Chen, Xue-rong Yu*, Jiao Zhang, Qing Yuan, Yu-guang Huang   

  1. Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
  • Received:2015-10-05 Published:2016-06-20 Online:2016-06-20

Abstract: Objective To evaluate the effect of point-of-care hemoglobin/hematocrit (POC HGB/HCT) devices and intraoperative blood salvage on the amount of perioperative allogeneic blood transfusion and blood conservation in clinical practice.Methods A total of 46 378 medical records of 22 selected hospitals were reviewed. The volume of allogeneic red blood cell and plasma, number of patients transfused, number of intraoperative autologous blood salvage, total volume of autologous blood transfusion, and amount of surgery in the year of 2011 and 2013 were tracked. Paired t-test was used in intra-group comparison, while t-test of two isolated samples carried out in inter-group comparison. P<0.05 was defined as statistically significant difference.Results In the hospitals where POC HGB/HCT device was used (n=9), the average allogeneic blood transfusion volume per 100 surgical cases in 2013 was significantly lower than that in 2011 (39.86±20.20 vs. 30.49±17.50 Units, t=3.522, P=0.008). In the hospitals without POC HGB/HCT meter, the index was not significantly different between 2013 and 2011. The average allogeneic blood transfusion volume was significantly reduced in 2013 than in 2011 in the hospitals where intraoperative autologous blood salvage ratio [autologous transfusion volume/(autologous transfusion volume+allogeneic transfusion volume)] was increased (n=12, t=2.290, P=0.042). No significant difference of the above index was found in the hospitals whose autologous transfusion ratio did not grow.Conclusion Intraoperative usage of POC HGB/HCT devices and increasing autologous transfusion ratio could reduce perioperative allogeneic blood transfusion.

Key words: point-of-care hemoglobin/hematocrit devices, autologous blood transfusion, blood management, red blood cell transfusion, transfusion practices

Copyright © 2018 Chinese Academy of Medical Sciences. All right reserved.
 
www.cmsj.cams.cn
京公安备110402430088 京ICP备06002729号-1  Powered by Magtech.

Supervised by National Health Commission of the People's Republic of China

9 Dongdan Santiao, Dongcheng district, Beijing, 100730 China

Tel: 86-10-65105897  Fax:86-10-65133074 

E-mail: cmsj@cams.cn  www.cmsj.cams.cn

Copyright © 2018 Chinese Academy of Medical Sciences

All right reserved.

京公安备110402430088  京ICP备06002729号-1