Chinese Medical Sciences Journal ›› 2012, Vol. 27 ›› Issue (3): 176-181.doi: 10.1016/S1001-9294(14)60052-3

• REVIEW • 上一篇    下一篇

Accuracy Validation for Medical Image Registration Algorithms: a Review△

Zhe Liu1, Xiang Deng2, Guang-zhi Wang1*   

  1. 1Department of Biomedical Engineering, Tsinghua University, Beijing 100084, China
    2Center for Medical Imaging Validation, Corporate Technology, Siemens Ltd.China, Beijing 100102, China
  • 收稿日期:2012-04-25 修回日期:2012-10-08 出版日期:2012-10-08 发布日期:2012-10-08
  • 作者简介:*Corresponding author Tel: 86-10-62783631, E-mail: wgz-dea@tsinghua.edu.cn

Accuracy Validation for Medical Image Registration Algorithms: a Review△

Zhe Liu1, Xiang Deng2, Guang-zhi Wang1*   

  1. 1Department of Biomedical Engineering, Tsinghua University, Beijing 100084, China
    2Center for Medical Imaging Validation, Corporate Technology, Siemens Ltd.China, Beijing 100102, China
  • Received:2012-04-25 Revised:2012-10-08 Published:2012-10-08 Online:2012-10-08
  • About author:*Corresponding author Tel: 86-10-62783631, E-mail: wgz-dea@tsinghua.edu.cn

摘要: Accuracy validation is essential to clinical application of medical image registration techniques.Registration validation remains a challenging problem in practice mainly due to lack of 'ground truth'.In this paper, an overview of current validation methods for medical image registration is presented with detailed discussion of their benefits and drawbacks.Special focus is on non-rigid registration validation.Promising solution is also discussed.

关键词: non-rigid registration, accuracy validation, digital phantom

Abstract: Accuracy validation is essential to clinical application of medical image registration techniques.Registration validation remains a challenging problem in practice mainly due to lack of 'ground truth'.In this paper, an overview of current validation methods for medical image registration is presented with detailed discussion of their benefits and drawbacks.Special focus is on non-rigid registration validation.Promising solution is also discussed.

Key words: non-rigid registration, accuracy validation, digital phantom

基金资助: △Supported by National Basic Research Program of China Grant (2011CB707701) and National Natural Science Foundation of China (81127003).

Copyright © 2018 Chinese Academy of Medical Sciences. All right reserved.
 
www.cmsj.cams.cn
京公安备110402430088 京ICP备06002729号-1  Powered by Magtech.

Supervised by National Health Commission of the People's Republic of China

9 Dongdan Santiao, Dongcheng district, Beijing, 100730 China

Tel: 86-10-65105897  Fax:86-10-65133074 

E-mail: cmsj@cams.cn  www.cmsj.cams.cn

Copyright © 2018 Chinese Academy of Medical Sciences

All right reserved.

京公安备110402430088  京ICP备06002729号-1