Chinese Medical Sciences Journal ›› 2018, Vol. 33 ›› Issue (1): 38-44.doi: 10.24920/11803
• Original Article • Previous Articles Next Articles
Liu Mengqi1, 2, Chen Zhiye1, 2, Ma Lin2, *()
Received:
2017-06-12
Published:
2018-03-30
Online:
2018-04-05
Contact:
Ma Lin
E-mail:cjr.malin@vip.163.com
Liu Mengqi, Chen Zhiye, Ma Lin. Reliability of Three Dimentional Pseudo-continuous Arterial Spin Labeling: A Volumetric Cerebral Perfusion Imaging with Different Post-labeling Time and Functional State in Health Adults[J].Chinese Medical Sciences Journal, 2018, 33(1): 38-44.
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
"
Acquisition parameters | CBF value [ml/(min·100 ml)] | ICC (95%CI) | |
---|---|---|---|
First scan | Second scan | ||
rs1.5 | |||
GM | 47.03±7.46 | 50.25±5.94 | 0.84 (0.05-0.97) |
WM | 43.09±5.53 | 44.19±5.83 | 0.92 (0.67-0.98) |
rs2.0 | |||
GM | 50.41±5.36 | 51.13±3.97 | 0.88 (0.54-0.97) |
WM | 45.30±4.60 | 46.25±4.50 | 0.94 (0.69-0.99) |
ft1.5 | |||
GM | 48.78±6.79 | 47.55±8.20 | 0.88 (0.54-0.97) |
WM | 42.18±4.93 | 42.66±5.22 | 0.92 (0.66-0.98) |
1. |
Gai ND, Chou YY, Pham D, et al.Reduced distortion artifact whole brain CBF mapping using blip-reversed non-segmented 3D echo planar imaging with pseudo-continuous arterial spin labeling. Magn Reson Imaging 2017; 44:119-24. doi: 10.1016/j.mri.2017.08. 011.
doi: 10.1016/j.mri.2017.08. 011 pmid: 28867670 |
2. |
Inoue Y, Tanaka Y, Hata H, et al.Arterial spin-labeling evaluation of cerebrovascular reactivity to acetazolamide in healthy subjects. AJNR Am J Neuroradiol 2014; 35(6):1111-6. doi: 10.3174/ajnr.A3815.
doi: 10.3174/ajnr.A3815 pmid: 24371025 |
3. |
Amann M, Achtnichts L, Hirsch JG, et al.3D GRASE arterial spin labelling reveals an inverse correlation of cortical perfusion with the white matter lesion volume in MS. Mult Scler 2012;18(11):1570-6. doi: 10.1177/1352458512441984.
doi: 10.1177/1352458512441984 pmid: 22466702 |
4. |
Shinohara Y, Kato A, Kuya K, et al.Perfusion MR imaging using a 3D pulsed continuous arterial spin-labeling method for acute cerebral infarction classified as branch atheromatous disease involving the lenticulostriate artery territory. AJNR Am J Neuroradiol 2017; 38(8):1550-4. doi: 10.3174/ajnr.A5247.
doi: 10.3174/ajnr.A5247 pmid: 28596191 |
5. |
Ozsunar Y, Mullins ME, Kwong K, et al.Glioma recurrence versus radiation necrosis? A pilot comparison of arterial spin-labeled, dynamic susceptibility contrast enhanced MRI, and FDG-PET imaging. Acad Radiol 2010; 17(3):282-90. doi: 10.1016/j.acra.2009.10.024.
doi: 10.1016/j.acra.2009.10.024 |
6. |
Xu G, Rowley HA, Wu G, et al.Reliability and precision of pseudo-continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O-water PET in elderly subjects at risk for Alzheimer’s disease. NMR Biomed 2010; 23(3):286-93. doi: 10.1002/nbm.1462.
doi: 10.1002/nbm.1462 |
7. |
Gutjahr FT, Gunster SM, Kampf T, et al.MRI-based quantification of renal perfusion in mice: improving sensitivity and stability in FAIR ASL. Z Med Phys 2017; 27(4):334-9. doi: 10.1016/j.zemedi.2017.02.001.
doi: 10.1016/j.zemedi.2017.02.001 pmid: 28431859 |
8. |
Campbell AM, Beaulieu C.Comparison of multislice and single-slice acquisitions for pulsed arterial spin labeling measurements of cerebral perfusion. Magn Reson Imaging 2006; 24(7):869-76. doi: 10.1016/j.mri.2006.03.011.
doi: 10.1016/j.mri.2006.03.011 pmid: 16916704 |
9. |
Floyd TF, Ratcliffe SJ, Wang J, et al.Precision of the CASL-perfusion MRI technique for the measurement of cerebral blood flow in whole brain and vascular territories. J Magn Reson Imaging 2003; 18(6):649-55. doi: 10.1002/jmri.10416.
doi: 10.1002/jmri.10416 pmid: 14635149 |
10. |
Jahng GH, Song E, Zhu XP, et al.Human brain: reliability and reproducibility of pulsed arterial spin-labeling perfusion MR imaging. Radiology 2005; 234(3):909-16. doi: 10.1148/radiol.2343031499.
doi: 10.1148/radiol.2343031499 pmid: 1851681 |
11. | O’Gorman RL, Coward HJ, Zelaya FO, et al. Reproducibility of pseudo-continuous ASL at 1.5T and 3T. Proc Intl Soc Mag Reson Med 2007; 15:1419. |
12. |
Parkes LM, Rashid W, Chard DT, et al.Normal cerebral perfusion measurements using arterial spin labeling: reproducibility, stability, and age and gender effects. Magn Reson Med 2004; 51(4):736-43. doi: 10.1002/mrm.20023.
doi: 10.1002/mrm.20023 pmid: 15065246 |
13. |
Yen YF, Field AS, Martin EM, et al.Test-retest reproducibility of quantitative CBF measurements using FAIR perfusion MRI and acetazolamide challenge. Magn Reson Med 2002; 47(4):921-8. doi: 10.1002/mrm.10140.
doi: 10.1002/mrm.10140 pmid: 11979571 |
14. |
Jiang L, Kim M, Chodkowski B, et al.Reliability and reproducibility of perfusion MRI in cognitively normal subjects. Magn Reson Imaging 2010;28(9):1283-9. doi: 10.1016/j.mri.2010.05.002.
doi: 10.1016/j.mri.2010.05.002 pmid: 2963675 |
15. |
Huang D, Wu B, Shi K, et al.Reliability of three-dimensional pseudo-continuous arterial spin labeling MR imaging for measuring visual cortex perfusion on two 3T scanners. PLoS One 2013; 8(11):e79471. doi: 10.1371/journal.pone.0079471.
doi: 10.1371/journal.pone.0079471 pmid: 3835829 |
16. |
Buijink AW, Broersma M, van der Stouwe AM, et al. Rhythmic finger tapping reveals cerebellar dysfunction in essential tremor. Parkinsonism Relat Disord 2015; 21(4):383-8. doi: 10.1016/j.parkreldis.2015.02.003.
doi: 10.1016/j.parkreldis.2015.02.003 pmid: 25703340 |
17. |
Jarnum H, Steffensen EG, Knutsson L, et al.Perfusion MRI of brain tumours: a comparative study of pseudo-continuous arterial spin labelling and dynamic susceptibility contrast imaging. Neuroradiology 2010; 52(4):307-17. doi: 10.1007/s00234-009-0616-6.
doi: 10.1007/s00234-009-0616-6 |
18. |
Dai W, Garcia D, de Bazelaire C, et al. Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields. Magn Reson Med 2008; 60(6):1488-97. doi: 10.1002/mrm.21790.
doi: 10.1002/mrm.21790 pmid: 19025913 |
19. |
Chen Z, Li L, Sun J, et al.Mapping the brain in type Ⅱ diabetes: voxel-based morphometry using DARTEL. Eur J Radiol 2012; 81(8):1870-6. doi: 10.1016/j.ejrad.2011.04.025.
doi: 10.1016/j.ejrad.2011.04.025 pmid: 21546180 |
20. |
Song XW, Dong ZY, Long XY, et al.REST: a toolkit for resting-state functional magnetic resonance imaging data processing. PLoS One 2011; 6(9):e25031. doi: 10.1371/journal.pone.0025031.
doi: 10.1371/journal.pone.0025031 pmid: 21949842 |
21. |
Hallgren KA.Computing Inter-rater reliability for observational data: an overview and tutorial. Tutor Quant Methods Psychol 2012; 8(1):23-34.
doi: 10.20982/tqmp.08.1.p023 pmid: 3402032 |
22. |
Pfefferbaum A, Chanraud S, Pitel AL, et al.Volumetric cerebral perfusion imaging in healthy adults: regional distribution, laterality, and repeatability of pulsed continuous arterial spin labeling (PCASL). Psychiatry Res 2010; 182(3):266-73. doi: 10.1016/j.pscychresns.
doi: 10.1016/j.pscychresns |
2010.02.010.
doi: 10.1016/j.pscychresns |
|
23. |
Kavanagh EC.The reversal sign. Radiology 2007; 245(3):914-5. doi: 10.1148/radiol.2453050112.
doi: 10.1148/radiol.2453050112 |
[1] | Atefeh Beigi-khoozani, Amirmohammad Merajikhah, Mahdieh Soleimani. Magnetic Resonance Imaging Findings of Olfactory Bulb in Anosmic Patients with COVID-19: A Systematic Review [J]. Chinese Medical Sciences Journal, 2022, 37(1): 23-30. |
[2] | Zhengyun Liang, Xiao Long, Elan Yang, Yunzhu Li, Zhujun Li, Min Xu, Bifen Zhang, Nanze Yu, Jiuzuo Huang. Reliability and Validity of the Chinese Version of the Lymphedema Quality of Life Questionnaire [J]. Chinese Medical Sciences Journal, 2021, 36(4): 295-306. |
[3] | Jia Xu, Xuan Wang, Zhengyu Jin, Qin Wang, Yan You, Shitian Wang, Tianyi Qian, Huadan Xue. Assessing Liver Function by T1 Maps on Gd-EOB-DTPA-Enhanced MRI for up to 50 Min in Rat Models of Liver Fibrosis: A Longer Hepatobiliary Time Period may Help [J]. Chinese Medical Sciences Journal, 2021, 36(2): 110-119. |
[4] | Wang Xuedan, Wang Shiwei, Wang Botao, Chen Zhiye. Effect of MR Field Strength on the Texture Features of Cerebral T2-FLAIR Images: A Pilot Study [J]. Chinese Medical Sciences Journal, 2020, 35(3): 248-253. |
[5] | Xu Yanhong,Yang Jia,Meng Jie,Wang Han. Targeted MR Imaging Adopting T1-Weighted Ultra-Small Iron Oxide Nanoparticles for Early Hepatocellular Carcinoma: An in vitro and in vivo Study [J]. Chinese Medical Sciences Journal, 2020, 35(2): 142-150. |
[6] | Xu Jia, Wang Xuan, Jin Zhengyu, You Yan, Wang Qin, Wang Shitian, Xue Huadan. Value of Texture Analysis on Gadoxetic Acid-enhanced MR for Detecting Liver Fibrosis in a Rat Model [J]. Chinese Medical Sciences Journal, 2019, 34(1): 24-32. |
[7] | Wang Botao, Fan Wenping, Xu Huan, Li Lihui, Zhang Xiaohuan, Wang Kun, Liu Mengqi, You Junhao, Chen Zhiye. Value of Magnetic Resonance Imaging Texture Analysis in the Differential Diagnosis of Benign and Malignant Breast Tumors [J]. Chinese Medical Sciences Journal, 2019, 34(1): 33-37. |
[8] | Li Ping, Zhu Liang, Wang Xuan, Xue Huadan, Wu Xin, Jin Zhengyu. Imaging Diagnosis of Type Ⅲ Choledochal Cyst: A Case Report [J]. Chinese Medical Sciences Journal, 2018, 33(3): 194-203. |
[9] | Li Lihui, Huang Houbin, Chen Zhiye. Early Diagnosis of Recurrent Optic Neuritis Using Contrast-Enhanced T2 Fluid-attenuated Inversion Recovery Imaging: a Case Report [J]. Chinese Medical Sciences Journal, 2018, 33(2): 130-134. |
[10] | Chen Zhiye, Liu Mengqi, Ma Lin. Cortical Thinning Pattern of Bulbar- and Spinal-onset Amyotrophic Lateral Sclerosis: a Surface-based Morphometry Study [J]. Chinese Medical Sciences Journal, 2018, 33(2): 100-106. |
[11] | Chen Zhiye,Liu Mengqi,Ma Lin. Gray Matter Volume Changes over the Whole Brain in the Bulbar- and Spinal-onset Amyotrophic Lateral Sclerosis: a Voxel-based Morphometry Study [J]. Chinese Medical Sciences Journal, 2018, 33(1): 20-28. |
[12] | Pan Haipeng, Lao Qun, Fei Zhenghua, Yang Li, Zhou Haichun, Lai Can. MR Lymphangiography for Focal Disruption of the Thoracic Duct in Chylothorax of an Infant: a Case Report and Literature Review△ [J]. Chinese Medical Sciences Journal, 2017, 32(4): 265-268. |
[13] | Chen Zhiye, Zang Xiujuan, Liu Mengqi, Liu Mengyu, Li Jinfeng, Gu Zhaoyan, Ma Lin. Abnormal Alterations of Cortical Thickness in 16 Patients with Type 2 Diabetes Mellitus: A Pilot MRI Study△ [J]. Chinese Medical Sciences Journal, 2017, 32(2): 75-82. |
[14] | Wang Ting, Ma Lin, Lou Xin, Bu Bo. Trigeminal Ganglioneuroma in the Middle-posterior Cranial Fossa: a Case Report△ [J]. Chinese Medical Sciences Journal, 2017, 32(2): 123-128. |
[15] | Yu Wang, Zi-yuan Liu, Wan-chen Dou, Wen-bin Ma, Ren-zhi Wang, Yi Guo. Application of Preoperative CT/MRI Image Fusion in Target Positioning for Deep Brain Stimulation [J]. Chinese Medical Sciences Journal, 2016, 31(3): 161-167. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||
|
Supervised by National Health Commission of the People's Republic of China
9 Dongdan Santiao, Dongcheng district, Beijing, 100730 China
Tel: 86-10-65105897 Fax:86-10-65133074
E-mail: cmsj@cams.cn www.cmsj.cams.cn
Copyright © 2018 Chinese Academy of Medical Sciences
All right reserved.
京公安备110402430088 京ICP备06002729号-1