Chinese Medical Sciences Journal ›› 2017, Vol. 32 ›› Issue (1): 65-68.doi: 10.24920/J1001-9242.2007.009
• Case Report • Previous Articles
Chen Xing1, Wang Lihua2, *(), Zhang Lixian2, Zhao Caihong2
Published:
2017-03-31
Online:
2017-04-10
Contact:
Wang Lihua
E-mail:clywlh@126.com
Chen Xing, Wang Lihua, Zhang Lixian, Zhao Caihong. IgG4-related Autoimmune Pancreatitis Mimicking Acute Pancreatitis: A Case Report[J].Chinese Medical Sciences Journal, 2017, 32(1): 65-68.
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
Figure 2.
Enhanced CT images 3 months after the initial diagnosis demonstrated the enlargement in the body and tail of the pancreas (white arrows in A and B); the enhancement of the body and tail was lower than that of the head during arterial phase (A), and higher than that of the head during portal phase (B). More effusion around the pancreas (black arrows in A and B) was observed than 3 months before. There still existed thickening of the left anterior renal fascia during arterial phase (white arrow in C), with more effusion around the left kidney (black arrow in C) than 3 months before."
Figure 3.
Non-enhanced CT imaging half a year after taking methylprednisolone demonstrated the swelling in the body and tail of the pancreas (white arrow in A), which was smaller than that half a year before. The effusion around the pancreas (black arrow in A) also decreased. It still showed thickening of the left anterior renal fascia (white arrow in B), while the effusion around the left kidney (black arrow in B) had relieved."
1. | Chari ST, Kloeppel G, Zhang L, et al.Histopathologic and clinical subtypes of autoimmune pancreatitis: the honolulu consensus document. Pancreatology 2010; 10: 664-72. |
2. | O'Reilly DA, Malde DJ, Duncan T, et al. Review of the diagnosis, classification and management of autoimmune pancreatitis. World J Gastrointest Pathophysiol 2014; 5:71-81. |
3. | Umehara H, Okazaki K, Masaki Y, et al.Comprehensive diagnostic criteria for IgG4-related disease (IgG4-RD), 2011. Mod Rheumatol 2012; 22:21-30. |
4. | Otsuki M, Chung JB, Okazaki K, et al.Asian diagnostic criteria for autoimmune pancreatitis: consensus of the Japan-Korea Symposium on Autoimmune Pancreatitis. J Gastroenterol 2008; 43:403-8. |
5. | Nizar AH, Toubi E.IgG4-related disease: case report and literature review. Auto Immun Highlights 2015; 6:7-15. |
6. | Khosroshahi A, Wallace ZS, Crowe JL, et al.International Consensus Guidance Statement on the management and treatment of IgG4-related disease. Arthritis Rheumatol 2015; 67:1688-99. |
7. | Kamisawa T, Okazaki K, Kawa S, et al.Amendment of the Japanese Consensus Guidelines for Autoimmune Pancreatitis, 2013 Ⅲ. Treatment and prognosis of autoimmune pancreatitis. J Gastroenterol 2014; 49:961-70. |
[1] | Dasheng Li,Dawei Wang,Nana Wang,Haiwang Xu,He Huang,Jianping Dong,Chen Xia. An Insight of the First Community Infected COVID-19 Patient in Beijing by Imported Case: Role of Deep Learning-Assisted CT Diagnosis [J]. Chinese Medical Sciences Journal, 2021, 36(1): 66-71. |
[2] | Jian Cao, Guorong Wang, Zhiwei Wang, Zhengyu Jin. CT Texture Analysis: A Potential Biomarker for Evaluating KRAS Mutational Status in Colorectal Cancer [J]. Chinese Medical Sciences Journal, 2020, 35(4): 306-314. |
[3] | Li Ping, Zhu Liang, Wang Xuan, Xue Huadan, Wu Xin, Jin Zhengyu. Imaging Diagnosis of Type Ⅲ Choledochal Cyst: A Case Report [J]. Chinese Medical Sciences Journal, 2018, 33(3): 194-203. |
[4] | Li Tao, Yang Li, Zhang Weiguo, Luo Chuncai, Huang Zili, Li Jinfeng, Li Xin. Midterm Follow-up of Coronary Artery Bypass Grafting with 64-Slice Multi-detector Computed Tomography: Identification of Risk Factors Affecting Graft Patency [J]. Chinese Medical Sciences Journal, 2018, 33(2): 69-76. |
[5] | Wang Ting, Ma Lin, Lou Xin, Bu Bo. Trigeminal Ganglioneuroma in the Middle-posterior Cranial Fossa: a Case Report△ [J]. Chinese Medical Sciences Journal, 2017, 32(2): 123-128. |
[6] | Li Tao, Zhao Shaohong, Li Jinfeng, Huang Zili, Luo Chuncai, Yang Li. Value of Multi-detector CT in Detection of Isolated Spontaneous Superior Mesenteric Artery Dissection [J]. Chinese Medical Sciences Journal, 2017, 32(1): 28-33. |
[7] | Yu Wang, Zi-yuan Liu, Wan-chen Dou, Wen-bin Ma, Ren-zhi Wang, Yi Guo. Application of Preoperative CT/MRI Image Fusion in Target Positioning for Deep Brain Stimulation [J]. Chinese Medical Sciences Journal, 2016, 31(3): 161-167. |
[8] | Da-ming Zhang, Xuan Wang, Hua-dan Xue, Zheng-yu Jin*, Hao Sun, Yu Chen, Yong-lan He. Determinants of Detection of Stones and Calcifications in the Hepatobiliary System on Virtual Nonenhanced Dual-energy CT [J]. Chinese Medical Sciences Journal, 2016, 31(2): 76-82. |
[9] | Zhi-wei Wang, Hua-dan Xue, Xiao-guang Li, Jie Pan, Xiao-bo Zhang, Zheng-yu Jin. Life-threatening Spontaneous Retroperitoneal Haemorrhage: Role of Multidetector CT-angiography for the Emergency Management [J]. Chinese Medical Sciences Journal, 2016, 31(1): 43-48. |
[10] | Lin Ou-yang, Guang-ming Lu. Features of Computed Tomography Perfusion of Mediastinal Lymphadenopathies: a Pathology-based Retrospective Study [J]. Chinese Medical Sciences Journal, 2015, 30(3): 162-169. |
[11] | Yong-han Peng, Wei Zhang, Xiao-feng Gao, Ying-hao Sun. Calyceal Diverticulum Mimicking Simple Parapelvic Cyst: a Case Report [J]. Chinese Medical Sciences Journal, 2015, 30(1): 56-58. |
[12] | Hao Sun, Hua-dan Xue, Zheng-yu Jin, Xuan Wang, Yu Chen, Yong-lan He, Da-ming Zhang, Liang Zhu. Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis [J]. Chinese Medical Sciences Journal, 2014, 29(4): 214-220. |
[13] | Xin-yi Hou, Pei-yi Gao*. Perihematomal Perfusion Typing and Spot Sign of Acute Intracerebral Hemorrhage with Multimode Computed Tomography: A Preliminary Study [J]. Chinese Medical Sciences Journal, 2014, 29(3): 139-143. |
[14] | Shao-long Sun,Feng Gao,Dong-xu Cui,Bao-sheng Wang*. Isolated Pancreatic Tuberculosis in Non-immunocompromised Patient Treated by Whipple’s Procedure: a Case Report [J]. Chinese Medical Sciences Journal, 2014, 29(1): 58-60. |
[15] | Lu Lin, Yi-ning Wang, Ling-yan Kong, Zheng-yu Jin, Guang-ming Lu, Zhao-qi Zhang, Jian Cao, Shuo Li, Lan Song, Zhi-wei Wang, Kang Zhou, Ming Wang. 128-slice Dual-source Computed Tomography Coronary Angiography in Patients with Atrial Fibrillation: Image Quality and Radiation Dose of Prospectively Electrocardiogram- triggered Sequential Scan Compared with Retrospectively Electrocardiogram-gated Spiral Scan [J]. Chinese Medical Sciences Journal, 2012, 27(4): 195-200. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||
|
Supervised by National Health Commission of the People's Republic of China
9 Dongdan Santiao, Dongcheng district, Beijing, 100730 China
Tel: 86-10-65105897 Fax:86-10-65133074
E-mail: cmsj@cams.cn www.cmsj.cams.cn
Copyright © 2018 Chinese Academy of Medical Sciences
All right reserved.
京公安备110402430088 京ICP备06002729号-1