Effect of Point-of-care Hemoglobin/Hematocrit Devices and Autologous Blood Salvage on Reduction of Perioperative Allogeneic Blood Transfusion
Chinese Medical Sciences JournalVol. 31, Issue 2, Pages: 83-88(2016)
Updated:2024-04-10
|
Share with wechat friends or circle of friends
Export references
Effect of Point-of-care Hemoglobin/Hematocrit Devices and Autologous Blood Salvage on Reduction of Perioperative Allogeneic Blood Transfusion
Affiliations:
Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College,Beijing,China,100730
Author bio:
Funds:
DOI:
CLC:
Published Online:20 June 2016,
Published:2016
Accepted:
Scan QR Code
Wei-yun Chen, Xue-rong Yu, Jiao Zhang, et al. [J]. Chinese medical sciences journal, 2016, 31(2): 83-88.
DOI:
Wei-yun Chen, Xue-rong Yu, Jiao Zhang, et al. [J]. Chinese medical sciences journal, 2016, 31(2): 83-88.DOI:
Effect of Point-of-care Hemoglobin/Hematocrit Devices and Autologous Blood Salvage on Reduction of Perioperative Allogeneic Blood Transfusion
Objective To evaluate the effect of point-of-care hemoglobin/hematocrit (POC HGB/HCT) devices and intraoperative blood salvage on the amount of perioperative allogeneic blood transfusion and blood conservation in clinical practice.Methods A total of 46 378 medical records of 22 selected hospitals were reviewed. The volume of allogeneic red blood cell and plasma
number of patients transfused
number of intraoperative autologous blood salvage
total volume of autologous blood transfusion
and amount of surgery in the year of 2011 and 2013 were tracked. Paired -test was used in intra-group comparison
while -test of two isolated samples carried out in inter-group comparison. <0.05 was defined as statistically significant difference.Results In the hospitals where POC HGB/HCT device was used (=9)
the average allogeneic blood transfusion volume per 100 surgical cases in 2013 was significantly lower than that in 2011 (39.86±20.20 . 30.49±17.50 Units
=3.522
=0.008). In the hospitals without POC HGB/HCT meter
the index was not significantly different between 2013 and 2011. The average allogeneic blood transfusion volume was significantly reduced in 2013 than in 2011 in the hospitals where intraoperative autologous blood salvage ratio [autologous transfusion volume/(autologous transfusion volume+allogeneic transfusion volume)] was increased (=12
=2.290
=0.042). No significant difference of the above index was found in the hospitals whose autologous transfusion ratio did not grow.Conclusion Intraoperative usage of POC HGB/HCT devices and increasing autologous transfusion ratio could reduce perioperative allogeneic blood transfusion.