目的
使用64层多排螺旋CT评价冠状动脉旁路移植术后左内乳动脉桥(LIMA)和大隐静脉桥(SVG)血管的通畅性
并探讨影响冠脉旁路移植术后中期桥血管通畅性的危险因素。
方法
收集2012年8月至2015年12月接受冠脉旁路移植手术及并术后采用64层多排螺旋CT(MDCT)随访的病例。根据CT表现将桥血管的通畅状态分为通畅及不通畅两大类。搜集患者的临床资料及影像资料并比较通畅组和不通畅组间的差异。采用单因素及多因素Logistic回归分析影响桥血管通畅性的危险因素。
结果
341个患者中有330支LIMA桥血管(326支吻合到前降支LAD
4支吻合到右冠状动脉RCA)和564支SVG桥血管(100支吻合到对角支D
220支吻合到钝缘支OM
238支吻合到右冠脉血流灌注区)。吻合到OM和右冠脉血流灌注区的SVG桥血管的通畅率明显高于吻合到D的通畅率(χ
2
=15.471
P=0.004)。吻合口近端靶血管狭窄程度小于90%是LIMA桥血管闭塞的独立危险因素(OR =0.015
95% CI=0.01-0.14
P=0.000)
而高脂血症(OR =1.52
95%
CI
=1.0-2.5
P=0.048)、糖尿病(OR =1.28
95%
CI
=0.90-2.26
P=0.045)及出现胸痛或呼吸困难等冠心病症状(OR=1.81
95% CI=1.33-4.15
P=0.003) 是SVG桥血管闭塞的独立危险因素.
结论
当冠状动脉旁路移植术吻合口近端前降支的狭窄率小于90%时
LIMA桥血管中期闭塞的危险性升高。高脂血症、糖尿病史及典型的冠心病的症状是SVG桥血管中期闭塞的危险因素。吻合口远端靶血管的选择也是影响SVG术后通畅性的重要因素。
Objective
To identify the risk factors that are associated with the midterm coronary artery bypass grafting (CABG) functionality by assessing patency of left internal mammary artery (LIMA) graft and saphenous vein (SV) graft with 64-slice multi-detector computed tomography (64-MDCT).
Methods
Patients who underwent CABG operation and postoperative 64-MDCT follow-up examinations from August 2012 to December 2015 were included. The graft patent status was classified into patent and poor patent according to MDCT findings predominantly on 3D reconstructed images by two radiologists. The clinical data and imaging findings of the patients were collected and compared between the patent group and poor patent group. Univariate analysis and the multivariate logistic regression analysis were performed to identify the risk factors that affect graft patency.
Results
Among 341 patients in the study
there were 330 LIMA grafts [326 anastomosed to the left anterior descending artery (LAD)
4 to right coronary artery (RCA)] and 564 SV grafts (SVG) [100 anastomosed to the diagonal branch (D)
226 to the obtuse marginal branch (OM)
and 238 to the RCA territory]
. The approximal vessel stenosis exceeding 90% occurred in 268 of 292 patent LIMA grafts
and in 1 of 34 poor patent grafts (
χ
2
=167
P
<
0.001). The patency rate was higher when SVG was anastomosed to OM (85.4%) or RCA territory (81.9%) than to D (69.0%) (
χ
2
=15.471
P
=0.004). The proximal target vessel stenosis
<
90% (
OR
= 0.015
95%
CI:
0.01-0.14
P
=0.000) was independently associated with the closure risk of LIMA grafts
the dyslipidemia (
OR
= 1.52
95%
CI
: 1.0-2.5
P
=0.048)
history of diabetes (
OR
= 1.28
95%
CI :
0.90-2.26
P
=0.045) and typical angina symptoms (
OR
=1.81
95%
CI :
1.33-4.15
P
=0.003) were independently associated with the closure risk of SVG.
Conclusions
The proximal LAD stenosis less than 90% was adversely associated with graft patency in LIMA recipients; dyslipidemia
diabetes and angina symptoms were associated with the midterm failure in SVG recipients. The choice of the target anastomosis sites may affect the patency of SVG.
Zheng Z , Zhang L , Hu S , et al . Risk factors and in-hospital mortality in Chinese patients undergoing coronary artery bypass grafting: analysis of a large multi-institutional Chinese database . J Thorac Cardiovasc Surg 2012 ; 144 : 355- 9 . e1 . doi: 10.1016/j.jtcvs.2011.10.012 10.1016/j.jtcvs.2011.10.012 . DOI: 10.1016/j.jtcvs.2012.03.020 http://doi.org/10.1016/j.jtcvs.2012.03.020 http://linkinghub.elsevier.com/retrieve/pii/S0022522312003340 http://linkinghub.elsevier.com/retrieve/pii/S0022522312003340
Parang P , Arora R . Coronary vein graft disease: pathogenesis and prevention . Can J Cardiol 2009 ; 25 ( 2 ): e57 - 62 . doi: 10.1016/s0828-282x(09)70486-6 10.1016/s0828-282x(09)70486-6 . DOI: 10.1016/S0828-282X(09)70486-6 http://doi.org/10.1016/S0828-282X(09)70486-6 http://linkinghub.elsevier.com/retrieve/pii/S0828282X09704866 http://linkinghub.elsevier.com/retrieve/pii/S0828282X09704866
von Kiedrowski H , Wiemer M , Franzke K , et al . Non-invasive coronary angiography: the clinical value of multi-slice computed tomography in the assessment of patients with prior coronary bypass surgery . Int J Cardiovasc Imaging 2009 ; 25 ( 2 ): 161 - 70 . doi: 10.1007/s10554-008-9361-x 10.1007/s10554-008-9361-x . DOI: 10.1007/s10554-008-9361-x http://doi.org/10.1007/s10554-008-9361-x http://link.springer.com/10.1007/s10554-008-9361-x http://link.springer.com/10.1007/s10554-008-9361-x
Di Lazzaro D , Crusco F . CT angio for the evaluation of graft patency . J Thorac Dis 2017 ; 9 ( suppl 4 ) S283 - 8 . doi: 10.21037/jtd.2017.03.111 10.21037/jtd.2017.03.111 . DOI: 10.21037/jtd.2017.03.111 http://doi.org/10.21037/jtd.2017.03.111 http://jtd.amegroups.com/ http://jtd.amegroups.com/
Yuceler Z , Kantarci M , Yuce I , et al . Follow-up of coronary artery bypass graft patency: diagnostic efficiency of high-pitch dual-source 256-slice MDCT findings . J Comput Assist Tomogr 2014 ; 38 ( 1 ): 61 - 6 . doi: 10.1097/RCT.0b013e3182a58a8c 10.1097/RCT.0b013e3182a58a8c . DOI: 10.1097/RCT.0b013e3182a58a8c http://doi.org/10.1097/RCT.0b013e3182a58a8c http://content.wkhealth.com/linkback/openurl?sid=WKPTLP:landingpage&an=00004728-201401000-00011 http://content.wkhealth.com/linkback/openurl?sid=WKPTLP:landingpage&an=00004728-201401000-00011
Koplay M , Guneyli S , Akbayrak H , et al . Diagnostic accuracy and effective radiation dose of high pitch dual source multidetector computed tomography in evaluation of coronary artery bypass graft patency . Wien Klin Wochenschr 2016 ; 128 ( 13-14 ): 488 - 94 . doi: 10.1007/s00508-016-1030-9 10.1007/s00508-016-1030-9 . DOI: 10.1007/s00508-016-1030-9 http://doi.org/10.1007/s00508-016-1030-9 http://link.springer.com/10.1007/s00508-016-1030-9 http://link.springer.com/10.1007/s00508-016-1030-9
Andreini D , Pontone G , Mushtaq S , et al . Diagnostic accuracy of multidetector computed tomography coronary angiography in 325 consecutive patients referred for transcatheter aortic valve replacement . Am Heart J 2014 ; 168 ( 3 ): 332 - 9 . doi: 10.1016/j.ahj.2014.04.022 10.1016/j.ahj.2014.04.022 . DOI: 10.1016/j.ahj.2014.04.022 http://doi.org/10.1016/j.ahj.2014.04.022 http://linkinghub.elsevier.com/retrieve/pii/S0002870314003561 http://linkinghub.elsevier.com/retrieve/pii/S0002870314003561
Jabara R , Chronos N , Klein L , et al . Comparison of multidetector 64-slice computed tomographic angiography to coronary angiography to assess the patency of coronary artery bypass grafts . Am J Cardiol 2007 ; 99 ( 11 ): 1529 - 34 . doi: 10.1016/j.amjcard.2007.01.026 10.1016/j.amjcard.2007.01.026 . DOI: 10.1016/j.amjcard.2007.01.026 http://doi.org/10.1016/j.amjcard.2007.01.026 http://linkinghub.elsevier.com/retrieve/pii/S0002914907003621 http://linkinghub.elsevier.com/retrieve/pii/S0002914907003621
Levisman JM , Budoff MJ , Karlsberg, RP. Long-term coronary artery graft patency as evaluated by 64-slice coronary computed tomographic angiography . Coron Artery Dis 2011 ; 22 ( 8 ): 521 - 5 . doi: 10.1097/MCA.0b013e32834b830e 10.1097/MCA.0b013e32834b830e . DOI: 10.1097/MCA.0b013e32834b830e http://doi.org/10.1097/MCA.0b013e32834b830e https://insights.ovid.com/crossref?an=00019501-201112000-00001 https://insights.ovid.com/crossref?an=00019501-201112000-00001
Yanagawa B , Algarni KD , Singh SK , et al . Clinical, biochemical, genetic predictors of coronary artery bypass graft failure . J Thorac Cardiovasc Surg 2014 ; 148 ( 2 ), 515 - 20 . e2. doi: 10.1016/j.jtcvs.2013.10.011 10.1016/j.jtcvs.2013.10.011 . DOI: 10.1016/j.jtcvs.2013.10.011 http://doi.org/10.1016/j.jtcvs.2013.10.011 http://linkinghub.elsevier.com/retrieve/pii/S0022522313012324 http://linkinghub.elsevier.com/retrieve/pii/S0022522313012324
Singh SK , Desai ND , Petroff SD , et al . The impact of diabetic status on coronary artery bypass graft patency: insights from the radial artery patency study . Circulation 2008 ; 118 ( 14 suppl ): S222 - 5 . doi: 10.1161/CIRCULATIONAHA.107.757161 10.1161/CIRCULATIONAHA.107.757161 . DOI: 10.1161/CIRCULATIONAHA.107.757161 http://doi.org/10.1161/CIRCULATIONAHA.107.757161 http://circ.ahajournals.org/cgi/doi/10.1161/CIRCULATIONAHA.107.757161 http://circ.ahajournals.org/cgi/doi/10.1161/CIRCULATIONAHA.107.757161
Choi JS , Cho KR , Kim KB . Does diabetes affect the postoperative outcomes after total arterial off-pump coronary bypass surgery in multivessel disease? Ann Thorac Surg 2005 ; 80 ( 4 ): 1353 - 60 . doi: 10.1016/j.athoracsur.2005.04.026 10.1016/j.athoracsur.2005.04.026 . DOI: 10.1016/j.athoracsur.2005.04.026 http://doi.org/10.1016/j.athoracsur.2005.04.026 http://linkinghub.elsevier.com/retrieve/pii/S0003497505007241 http://linkinghub.elsevier.com/retrieve/pii/S0003497505007241
Fitzgibbon GM , Kafka HP , Leach AJ , et al . Coronary bypass graft fate and patient outcome: angiographic follow-up of 5065 grafts related to survival and reoperation in 1388 patients during 25 years . J Am Coll Cardiol 1996 ; 28 ( 3 ): 616 - 26 . doi: 10.1016/0735-1097(96)00206-9 10.1016/0735-1097(96)00206-9 . DOI: 10.1016/0735-1097(96)00206-9 http://doi.org/10.1016/0735-1097(96)00206-9 http://linkinghub.elsevier.com/retrieve/pii/0735109796002069 http://linkinghub.elsevier.com/retrieve/pii/0735109796002069
Kim JB , Kang JW , Song H , et al . Late improvement in graft patency after coronary artery bypass grafting: serial assessment with multidetector computed tomography in the early and late postoperative settings . J Thorac Cardiovasc Surg 2011 ; 142 ( 4 ): 793 - 9 . doi: 10.1016/j.jtcvs.2010.12.002 10.1016/j.jtcvs.2010.12.002 . DOI: 10.1016/j.jtcvs.2010.12.002 http://doi.org/10.1016/j.jtcvs.2010.12.002 http://linkinghub.elsevier.com/retrieve/pii/S0022522310014327 http://linkinghub.elsevier.com/retrieve/pii/S0022522310014327
Nwasokwa ON . Coronary artery bypass graft disease . Ann Intern Med 1995 ; 123 ( 7 ): 528 - 45 . doi: 10.7326/0003-4819-123-7-199510010-00009 10.7326/0003-4819-123-7-199510010-00009 . DOI: 10.7326/0003-4819-123-7-199510010-00009 http://doi.org/10.7326/0003-4819-123-7-199510010-00009 http://annals.org/article.aspx?doi=10.7326/0003-4819-123-7-199510010-00009 http://annals.org/article.aspx?doi=10.7326/0003-4819-123-7-199510010-00009
Noyez L . The evolution of repeat coronary artery surgery . EuroIntervention Supplement 2009 ; 5 ( suppl D ): 30 - 3 . http://www.ncbi.nlm.nih.gov/pubmed/19736067 http://www.ncbi.nlm.nih.gov/pubmed/19736067
Harskamp RE , Williams JB , Hill RC , et al . Saphenous vein graft failure and clinical outcomes: toward a surrogate end point in patients following coronary artery bypass surgery? Am Heart J 2013 ; 165 ( 5 ): 639 - 43 . doi: 10.1016/j.ahj.2013.01.019 10.1016/j.ahj.2013.01.019 . DOI: 10.1016/j.ahj.2013.01.019 http://doi.org/10.1016/j.ahj.2013.01.019 http://linkinghub.elsevier.com/retrieve/pii/S0002870313000768 http://linkinghub.elsevier.com/retrieve/pii/S0002870313000768
Chan M , Ridley L , Dunn DJ , et al . A systematic review and meta-analysis of multidetector computed tomography in the assessment of coronary artery bypass grafts . Int J Cardiol 2016 ; 221 : 898 - 905 . doi: 10.1016/j.ijcard.2016.06.264 10.1016/j.ijcard.2016.06.264 . DOI: 10.1016/j.ijcard.2016.06.264 http://doi.org/10.1016/j.ijcard.2016.06.264 http://linkinghub.elsevier.com/retrieve/pii/S0167527316312670 http://linkinghub.elsevier.com/retrieve/pii/S0167527316312670
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621