FOLLOWUS
Department of Ultrasonography, Guangzhou General Hospital of Guangzhou Military Command of People’s Liberation Army, Guangzhou 510010, China
*Corresponding author Tel: 86-20-88653449, Fax: 86-20-88653450, E-mail: 457563258@qq.com
收稿日期:2014-05-16,
网络出版日期:2015-04-20,
纸质出版日期:2015-04
Scan QR Code
Evaluation of Tubal Patency with Transvaginal Three- dimensional Hysterosalpingo-contrast Sonography△[J]. 中国医学科学杂志(英文版), 2015,30(2):70-75.
Cheng Qi, Wang Sha-sha, Zhu Xian-sheng, et al. Evaluation of Tubal Patency with Transvaginal Three- dimensional Hysterosalpingo-contrast Sonography△[J]. Chinese medical sciences journal, 2015, 30(2): 70-75.
Evaluation of Tubal Patency with Transvaginal Three- dimensional Hysterosalpingo-contrast Sonography△[J]. 中国医学科学杂志(英文版), 2015,30(2):70-75. DOI:
Cheng Qi, Wang Sha-sha, Zhu Xian-sheng, et al. Evaluation of Tubal Patency with Transvaginal Three- dimensional Hysterosalpingo-contrast Sonography△[J]. Chinese medical sciences journal, 2015, 30(2): 70-75. DOI:
Objective
To investigate diagnostic efficacy of transvaginal three-dimensional hysterosalpingo-contrast sonography (3D-HyCoSy) in assessing tubal patency with chromolaporoscopy.
Methods
A total of 157 infertile women underwent 3D-HyCoSy to evaluate tubal patency. Among these patients
39 patients were also examined by chromolaporoscopy. The concordance of the two clinical assessment methods was analyzed by the Kappa coefficient test.
Results
Among the 306 oviducts examined by 3D-HyCoSy
99 (32.4%) were patent
126 (41.2%) partially obstructed
and 81 (26.5%) completely obstructed. Diagnostic results with 3D-HyCoSy were not statistically different from those obtained in the 39 women (78 oviducts) who also underwent chromolaporoscopy
and the two methods showed a high concordance (
κ
=0.747
P
=0.000). The 3D-HyCoSy procedure had a sensitivity of 84.8% (28/33)
a specificity of 96.2% (25/26)
and positive and negative predictive values of 93.3% (28/30) and 86.2% (25/29) respectively.
Conclusion
Transvaginal 3D-HyCoSy can accurately reveal the spatial path and morphology of the oviduct and is a safe and effective method to evaluate tubal patency.
Shalve J , Krissi H , Blankstein J , et al. Modified hysterosalpingography during infertility work-up: Use of contrast medium and saline to investigate mechanical factors. Fertilsteril 2000 ; 74 : 372 - 5 .
Kupesic S , Plavsic BM. 2D and 3D hysterosalpingo contrast sonography in the assessment of uterine cavity and tubal patency. Eur J Obstet Gynecol Reprod Biol 2007 ; 133 : 64 - 9 .
Wang SS , Li YK , Cheng Q , et al. Evaluation of tubal patency by transvaginal reconstructive three-dimensional hysterosalpingo-contrast sonography. Chin J Ultrasound Med 2010 ; 26 : 932 - 4 .
Millo T , Misra R , Girdhar S , et al. Fatal pulmonary oedema following laparoscopic chromopertubation. Natl Med J India 2006 ; 19 : 78 - 9 .
Yang SJ , Gong WB , Hu ML , et al. Study on the fallopian tube patency using real-time harmonic contrast imaging with low mechanical index. J Ultrasound Clin Med 2006 ; 9 : 340 - 3 .
El-Sherbiny W , Nasr AS. Value of 3-dimensional sonohy- sterography in infertility work-up. J Minim Invasive Gynecol 2011 ; 18 : 54 - 8 .
Gao XW , He W , Wang LX , et al. SonoVue-hysterosal- pingo-contrast sonography assessment of tubal patency. Chin J Med Imaging Techno 2008 ; 24 : 1799 - 8028 .
Bocca S M , Oehninger S , Stadtmauer L , et al. A study of the cost, accuracy, and benefits of 3-dimensional sonography compared with hysterosalpingography in women with uterine abnormalities. J Ultrasound Med 2012 ; 31 : 81 - 5 .
Exacoustos C , Di Giovanni A , Szabolcs B , et al. Automated sonographic tubal patency evaluation with three dimensional coded contrast imaging (CCI) during hysterosalpingo-contrast sonography (HyCoSy). Ultrasound Obstet Gynecol 2009 ; 34 : 609 - 12 .
Fenzl V. Effect of different ultrasound contrast materials and temperatures on patient comfort during intrauterine and tubal assessment for infertility. Eur J Radiol 2012 ; 81 : 4143 - 5 .
Lovsin B , Tomazevic T. Hysterosalpingo-contrast sonography for infertility investigation. Int J Gynaecol Obstet 2010 ; 108 : 70 - 1 .
Luciano DE , Exacoustos C , Johns DA , et al. Can hysterosalpingo-contrast sonography replace hysterosalpin- gography in confirming tubal blockage after hysteroscopic sterilization and in the evaluation of the uterus and tubes in infertile patients? Am J Obstet Gynecol 2011 ; 204 : 71 - 9 .
Nicolau C , Catalá V , Vilana R , et al. Evaluation of hepatocellular carcinoma using SonoVue, a second generation ultrasound contrast agent: Correlation with cellular differentiation. Eur Radiol 2004 ; 14 : 1092 - 9 .