Normative Measurements of Extraocular Musculature by Multislice Computed Tomography
中国医学科学杂志(英文版)2012年第4期 页码:232-236
• Original Article •|Updated:2024-04-10
|
Share with wechat friends or circle of friends
Export references
Normative Measurements of Extraocular Musculature by Multislice Computed Tomography
Affiliations:
1. Department of Radiology
2. Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College,Beijing,China,100730
Author bio:
Funds:
DOI:
中图分类号:
网络出版日期:2013-01-07,
纸质出版日期:2012
Accepted:
Scan QR Code
Zhu-hua Zhang, Yu Chen, Yun Wang, 等. Normative Measurements of Extraocular Musculature by Multislice Computed Tomography[J]. 中国医学科学杂志(英文版), 2012,(4):232-236.
Zhu-hua Zhang, Yu Chen, Yun Wang, et al. Normative Measurements of Extraocular Musculature by Multislice Computed Tomography[J]. Null, 2012, (4): 232-236.
Zhu-hua Zhang, Yu Chen, Yun Wang, 等. Normative Measurements of Extraocular Musculature by Multislice Computed Tomography[J]. 中国医学科学杂志(英文版), 2012,(4):232-236.DOI:
Zhu-hua Zhang, Yu Chen, Yun Wang, et al. Normative Measurements of Extraocular Musculature by Multislice Computed Tomography[J]. Null, 2012, (4): 232-236.DOI:
Normative Measurements of Extraocular Musculature by Multislice Computed Tomography
Objective To establish the normal measurements of diameter of extraocular muscles (EOMs) by multislice computed tomography (CT). Methods Orbits of 50 volunteers (25 male and 25 female) were scanned with a multislice CT scanner. For each subject
one axial image at the central level of the eyeball
one coronal image about 1 cm behind globe
and two oblique sagittal images respectively along the left and right optic nerve were used for measurements of the thickness and width of EOMs. The statistic significance of measurement value between male and female and between left and right eyes was evaluated. Results There were no significant differences in the thickness and width of superior muscle group
lateral rectus
medial rectus
lateral rectus
superior oblique
inferior oblique and the thickness of levator palpebrae superioris between the left and right eyes as well as between male and female groups (all P>0.05). The thickness of superior muscle group and inferior rectus had not significant difference (2.9±0.7 vs. 3.3±0.8 mm
P=0.162)
while the thickness of medial rectus was significantly higher than that of lateral rectus (3.1±0.5 vs. 2.2±0.6 mm
P=0.000). Conclusions The CT measurement of extraocular musculature is simple and time-saving and can be applied in the clinical work. The normative data obtained may be useful in determining pathologic enlargement of the EOMs in both thyroid-associated orbitopathy patients and other various orbital conditions.
Abstract
Objective To establish the normal measurements of diameter of extraocular muscles (EOMs) by multislice computed tomography (CT). Methods Orbits of 50 volunteers (25 male and 25 female) were scanned with a multislice CT scanner. For each subject
one axial image at the central level of the eyeball
one coronal image about 1 cm behind globe
and two oblique sagittal images respectively along the left and right optic nerve were used for measurements of the thickness and width of EOMs. The statistic significance of measurement value between male and female and between left and right eyes was evaluated. Results There were no significant differences in the thickness and width of superior muscle group
lateral rectus
medial rectus
lateral rectus
superior oblique
inferior oblique and the thickness of levator palpebrae superioris between the left and right eyes as well as between male and female groups (all P>0.05). The thickness of superior muscle group and inferior rectus had not significant difference (2.9±0.7 vs. 3.3±0.8 mm
P=0.162)
while the thickness of medial rectus was significantly higher than that of lateral rectus (3.1±0.5 vs. 2.2±0.6 mm
P=0.000). Conclusions The CT measurement of extraocular musculature is simple and time-saving and can be applied in the clinical work. The normative data obtained may be useful in determining pathologic enlargement of the EOMs in both thyroid-associated orbitopathy patients and other various orbital conditions.