FOLLOWUS
Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu 610041, China
网络出版日期:2015-06-20,
纸质出版日期:2015-06
Scan QR Code
Accuracy of a Simple Digital Templating in Primary Uncemented Total Hip Arthroplasty△[J]. 中国医学科学杂志(英文版), 2015,30(3):150-155.
Si Hai-bo, Zeng Yi, Cao Fei, et al. Accuracy of a Simple Digital Templating in Primary Uncemented Total Hip Arthroplasty△[J]. Chinese medical sciences journal, 2015, 30(3): 150-155.
Accuracy of a Simple Digital Templating in Primary Uncemented Total Hip Arthroplasty△[J]. 中国医学科学杂志(英文版), 2015,30(3):150-155. DOI:
Si Hai-bo, Zeng Yi, Cao Fei, et al. Accuracy of a Simple Digital Templating in Primary Uncemented Total Hip Arthroplasty△[J]. Chinese medical sciences journal, 2015, 30(3): 150-155. DOI:
Objective
To introduce a simple preoperative digital templating in uncemented total hip arthroplasty (THA) and to determine its accuracy for preoperative size selection of the prostheses.
Methods
A prospective study of digital planned THAs was performed on 90 hips with different types of prostheses from August 2013 to Angust 2014. The plastic templates of different types of prostheses were scanned for desired digital templating and the scanned images were then processed to the transparent
digital templates using Photoshop software. We calibrated the scales of the digital templates with the preoperative radiographs
and then selected the right size of the component. The preoperatively digital planned component sizes were compared to the actual sizes used in the operation
as well as the preoperatively traditional planned sizes.
Results
In either cup or stem templating
no difference was found among the groups with different types of prostheses
and the accuracy of digital templating was statistically higher than traditional templating. In cup templating
digital planned and implanted cup sizes were identical in 43.33% of the cases
78.89% of the cup sizes were predicted within 1 size (± 2mm) and 95.56% were predicted within 2 sizes (±4 mm)
all significantly higher than the results of traditional planned sizes (30.00%
P
=0.044; 61.11%
P
=0.007; 82.22%
P
=0.004). The exact femoral stem size was predicted in 40.00% of cases using the digital templating
84.44% of stem sizes were predicted within 1 size
and 93.33% within 2 sizes
better than using traditional templating (25.56%
P
=0.028; 53.33%
P
<
0.001; 77.77%
P
=0.003).
Conclusion
This simple digital preoperative templating is an accurate and reproducible process to preoperatively predict the implant size of uncemented THA.
Kawai T , Tanaka C , Kanoe H. Total hip arthroplasty for Crowe IV hip without subtrochanteric shortening osteo- tomy—a long term follow up study. BMC Musculoskelet Disord 2014 ; 15 : 72 .
Issa K , Johnson AJ , Naziri Q , et al. Hip osteonecrosis: does prior hip surgery alter outcomes compared to an initial primary total hip arthroplasty? J Arthroplasty 2014 ; 29 : 162 - 6 .
Tezuka T , Inaba Y , Kobayashi N , et al. Long-term results of porous-coated anatomic total hip arthroplasty for patients with osteoarthritis of the hip. J Arthroplasty 2014 ; 29 : 2251 - 5 .
Norman TL , Shultz T , Noble G , et al. Bone creep and short and long term subsidence after cemented stem total hip arthroplasty (THA). J Biomech 2013 ; 46 : 949 - 55 .
Van Eynde E , Hendrickx M , Scheerlinck T. Uncemented femoral stem design influences the occurrence rate of postoperative fractures after primary hip arthroplasty: a comparison of the Image and Profile stems. Acta Orthop Belg 2010 ; 76 : 189 - 98 .
Kniesel B , Konstantinidis L , Hirschmuller A , et al. Digital templating in total knee and hip replacement: an analysis of planning accuracy. Int Orthop 2014 ; 38 : 733 - 9 .
7.Heep H , Xu J , Löchteken C , et al . A simple and convenient method guide to determine the magni- fication of digital X-rays for preoperative planning in total hip arthroplasty. Orthop Rev 2012; 4: e12. [ 2014 - 11-01]. http://www.ncbi.nlm.nih.gov/pmc/articles/PMC 3348687/ http://www.ncbi.nlm.nih.gov/pmc/articles/PMC 3348687/
Kosashvili Y , Shasha N , Olschewski E , et al. Digital versus conventional templating techniques in preo- perative planning for total hip arthroplasty. Can J Surg 2009 ; 52 : 6 - 11 .
Jamali AA. Digital templating and preoperative deformity analysis with standard imaging software. Clin Orthop Relat Res 2009 ; 467 : 2695 - 704 .
Iorio R , Siegel J , Specht LM , et al. A comparison of acetate vs . digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? J Arthroplasty 2009 ; 24 : 175 - 9 .
González Della Valle A , Comba F , Taveras N , et al . The utility and precision of analogue and digital preoperative planning for total hip arthroplasty. Int Orthop 2008 ; 32 : 289 - 94 .
Gamble P , de Beer J , Petruccelli D , et al . The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplasty 2010 ; 25 : 529 - 32 .
White SP , Shardlow DL. Effect of introduction of digital radiographic techniques on pre-operative templating in orthopaedic practice. Ann R Coll Surg Engl 2005 ; 87 : 53 - 4 .
Suh KT , Cheon SJ , Kim DW. Comparison of preoperative templating with postoperative assessment in cementless total hip arthroplasty. Acta Orthop Scand 2004 ; 75 : 40 - 4 .
Carter LW , Stovall DO , Young TR. Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty 1995 ; 10 : 507 - 13 .
Unnanuntana A , Wagner D , Goodman SB. The accuracy of preoperative templating in cementless total hip arthroplasty. J Arthroplasty 2009 ; 24 : 180 - 6 .
Kumar PG , Kirmani SJ , Humberg H , et al. Reproducibility and accuracy of templating uncemented THA with digital radiographic and digital TraumaCad templating software. Orthopedics 2009 ; 32 : 815 .
Steinberg EL , Shasha N , Menahem A , et al. Preoperative planning of total hip replacement using the TraumaCad system. Arch Orthop Trauma Surg 2010 ; 130 : 1429 - 32 .
Shahril SR , McHugh G, Collins DA. Accuracy of digital preoperative templating in 100 consecutive uncemented total hip arthroplasties: a single surgeon series. J Arthroplasty 2013 ; 28 : 331 - 7 .
The B , Verdonschot N, van Horn JR, et al. Digital versus analogue preoperative planning of total hip arthro- plasties: a randomized clinical trial of 210 total hip arthroplasties. J Arthroplasty 2007 ; 22 : 866 - 70 .
Chalazonitis AN , Koumarianos D , Tzovara J , et al. How to optimize radiological images captured from digital cameras, using the Adobe Photoshop 6.0 program. J Digit Imaging 2003 ; 16 : 216 - 29 .
Park JS , Chung MS , Hwang SB , et al. Technical report on semiautomatic segmentation using the Adobe Photoshop. J Digit Imaging 2005 ; 18 : 333 - 43 .
Bayne CO , Krosin M , Barber TC. Evaluation of the accuracy and use of x-ray markers in digital templating for total hip arthroplasty. J Arthroplasty 2009 ; 24 : 407 - 13 .
Kulkarni A , Partington P , Kelly D , et al. Disc calibration for digital templating in hip replacement. J Bone Joint Surg Br 2008 ; 90 : 1623 - 6 .
Berend KR , Lombardi AV , Jr. Intraoperative femur fracture is associated with stem and instrument design in primary total hip arthroplasty. Clin Orthop Relat Res 2010 ; 468 : 2377 - 81 .
Tripuraneni KR , Archibeck MJ , Junick DW , et al. Common errors in the execution of preoperative templating for primary total hip arthroplasty. J Arthroplasty 2010 ; 25 : 1235 - 9 .
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621