COMPARISON OF CELLULOSE ACETATE POLYMER AND ELECTROLYTIC DETACHABLE COILS FOR TREATMENT OF CANINE ANEURYSMAL MODELS
中国医学科学杂志(英文版)2002年0卷第1期 页码:47-51
Updated:2024-04-10
|
Share with wechat friends or circle of friends
Export references
COMPARISON OF CELLULOSE ACETATE POLYMER AND ELECTROLYTIC DETACHABLE COILS FOR TREATMENT OF CANINE ANEURYSMAL MODELS
Affiliations:
Author bio:
Funds:
DOI:
中图分类号:R73-36
纸质出版日期:2002
Accepted:
Scan QR Code
COMPARISON OF CELLULOSE ACETATE POLYMER AND ELECTROLYTIC DETACHABLE COILS FOR TREATMENT OF CANINE ANEURYSMAL MODELS[J]. 中国医学科学杂志(英文版), 2002,0(1):47-51.
COMPARISON OF CELLULOSE ACETATE POLYMER AND ELECTROLYTIC DETACHABLE COILS FOR TREATMENT OF CANINE ANEURYSMAL MODELS[J]. Chinese medical sciences journal, 2002, 0(1): 47-51.
COMPARISON OF CELLULOSE ACETATE POLYMER AND ELECTROLYTIC DETACHABLE COILS FOR TREATMENT OF CANINE ANEURYSMAL MODELS[J]. 中国医学科学杂志(英文版), 2002,0(1):47-51.DOI:
COMPARISON OF CELLULOSE ACETATE POLYMER AND ELECTROLYTIC DETACHABLE COILS FOR TREATMENT OF CANINE ANEURYSMAL MODELS[J]. Chinese medical sciences journal, 2002, 0(1): 47-51.DOI:
COMPARISON OF CELLULOSE ACETATE POLYMER AND ELECTROLYTIC DETACHABLE COILS FOR TREATMENT OF CANINE ANEURYSMAL MODELS
摘要
Abstract
Electrolytic detachable coils (EDC) have been the main embolic materi als for intracranial aneurysms. Liquid aneurysmal embolic materials represented by cellulose acetate polymer (CAP) are still in controversy. In this research
t he embolization results and pathological reactions after embolization of canine aneurysmal models with EDC or CAP were observed and compared. Methods. The canine aneurysmal models constructed by anastomosis of venous pouch es were randomly grouped. The aneurysms were respectively occluded with CAP and electrolytic detachable coils that was named by Wu electrolytic detachable coil (WEDC) and made by us. Angiogram follow ups were performed at 24 hour
2 week
and 2 month after embolization. The occluded aneurysms were dissected in each stage for light microscopic
electron microscopic
and histochemical research. Results. The effect of embolization was significantly better with WEDC than that with CAP . Post embolized complications such as aneurysm rupture and stenosis of parent arteries could only be found in CAP group. Pathol ogical research showed that CAP mass could packed the aneurysms more densely tha n coils. Acute chemical damage of aneurysmal wall and inflammatory cell infiltra tion was prominently found in early stage after CAP embolization. Organization of thrombus inside aneurysms and formation of endothelial tissue over the orific es of aneurysmal necks could be found in both groups 2 months after embolization . But parts of coils might be exposed outside endothelial layer. Conclusions. EDC are still the most safe
efficient
and reliable instruments to embolize aneurysm. CAP should be improved further to solve the problem of stron g chemical corrosion and difficulty in control before it is widely used.