THREE- DIMENSIONAL CORRECTION OF SCOLIOSIS USING TSRH INSTRUMENTATION
中国医学科学杂志(英文版)2001年0卷第2期 页码:98-102
Updated:2024-04-10
|
Share with wechat friends or circle of friends
Export references
THREE- DIMENSIONAL CORRECTION OF SCOLIOSIS USING TSRH INSTRUMENTATION
Affiliations:
Author bio:
Funds:
DOI:
中图分类号:R681.5
纸质出版日期:2001
Accepted:
Scan QR Code
THREE- DIMENSIONAL CORRECTION OF SCOLIOSIS USING TSRH INSTRUMENTATION[J]. 中国医学科学杂志(英文版), 2001,0(2):98-102.
THREE- DIMENSIONAL CORRECTION OF SCOLIOSIS USING TSRH INSTRUMENTATION[J]. Chinese medical sciences journal, 2001, 0(2): 98-102.
THREE- DIMENSIONAL CORRECTION OF SCOLIOSIS USING TSRH INSTRUMENTATION[J]. 中国医学科学杂志(英文版), 2001,0(2):98-102.DOI:
THREE- DIMENSIONAL CORRECTION OF SCOLIOSIS USING TSRH INSTRUMENTATION[J]. Chinese medical sciences journal, 2001, 0(2): 98-102.DOI:
THREE- DIMENSIONAL CORRECTION OF SCOLIOSIS USING TSRH INSTRUMENTATION
摘要
Abstract
Objective. To evaluate the results of TSRH instrumentation in the correction of coronal
sagittal and rotational deformity of scoliosis. Methods. From January 1998 to December 1999
thirty- two consecutive patients (6 males
26 females) with scoliosis underwent anterior or posterior spinal instrumentation and fusion using TSRH instrumentation. Of these cases
21 were idiopathic scoliosis and 11 were congenital scoliosis. The average age at surgery was 16.4 years (range
11~ 45 years). The mean Cobb angle at surgery was 71 .2 (range
44~ 125 ) in the coronal plane
and 49.2 ( range
16~ 67 ) in the sagittal plane. Rotational deformity (Nash- Moe) ranged from I to III degree. Preoperative apical translation averaged 4.8 cm (range
3~ 9 cm). Results. The average follow- up duration was 13.3 months (range
10~ 24 months).At the final follow- up
the mean Cobb angle in the coronal plane was 26. 6 (range
10~ 73 )
with a 63.8% of improvement. Sagittal alignment was well maintained with a mean Cobb angle of 28 ( range
10~ 45 ). The average correction of rotation of the apical vertebra was I degree. The average apical translation was 1.6 cm (range
0.5~ 5.0 cm) representing a correction rate of 66
7% . Complication was noted in two cases with an incidence of 3.1%
one case had superficial infection and the other one had lower hook dislocation.There was no neurologic deficit and pseudoarthrodesis in this series. Conclusion. TSRH instrumentation is an effective and convenient three- dimensional correction system with a lower rate of complication
which can not only correct the coronal and rotational deformity