CHANGES OF PLASMA DYNORPHIN LEVELS BEFORE AND AFTER PERCUTANEOUS BALLOON MITRAL COMMISSUROTOMY IN PATIENTS WITH MITRAL STENOS
中国医学科学杂志(英文版)1995年第4期
Updated:2024-04-10
Share with wechat friends or circle of friends
Export references
CHANGES OF PLASMA DYNORPHIN LEVELS BEFORE AND AFTER PERCUTANEOUS BALLOON MITRAL COMMISSUROTOMY IN PATIENTS WITH MITRAL STENOS
Affiliations:
Author bio:
Funds:
DOI:
中图分类号:R363
纸质出版日期:1995
Accepted:
Scan QR Code
[1]尹瑞兴,陶新智,曾知恒,赵定菁,朱树雄,夏树楹.CHANGES OF PLASMA DYNORPHIN LEVELS BEFORE AND AFTER PERCUTANEOUS BALLOON MITRAL COMMISSUROTOMY IN PATIENTS WITH MITRAL STENOS[J].Chinese Medical Sciences Journal,1995(04):214-219.
CHANGES OF PLASMA DYNORPHIN LEVELS BEFORE AND AFTER PERCUTANEOUS BALLOON MITRAL COMMISSUROTOMY IN PATIENTS WITH MITRAL STENOSIS[J]. Chinese medical sciences journal, 1995, (4).
[1]尹瑞兴,陶新智,曾知恒,赵定菁,朱树雄,夏树楹.CHANGES OF PLASMA DYNORPHIN LEVELS BEFORE AND AFTER PERCUTANEOUS BALLOON MITRAL COMMISSUROTOMY IN PATIENTS WITH MITRAL STENOS[J].Chinese Medical Sciences Journal,1995(04):214-219.DOI:
CHANGES OF PLASMA DYNORPHIN LEVELS BEFORE AND AFTER PERCUTANEOUS BALLOON MITRAL COMMISSUROTOMY IN PATIENTS WITH MITRAL STENOSIS[J]. Chinese medical sciences journal, 1995, (4).DOI:
CHANGES OF PLASMA DYNORPHIN LEVELS BEFORE AND AFTER PERCUTANEOUS BALLOON MITRAL COMMISSUROTOMY IN PATIENTS WITH MITRAL STENOS
Plasma dynorphin A1-13 levels were measured in 33 patients with mitral stenosis before and after percutaneous balloon mitral commissurotomy (PBMC). The results show that the basal levels of plasma dynorphin in blood from the antecubital vein in the patients were significantly higher than those in 31 healthy control subjects. The increase in circulating dynorphin closely correlated with the functional cardiac status and the presence of atrial fibrillation. Ten to fifteen minutes after PBMC
plasma dynorphin levels in blood from the femoral vein increased significantly. Seventy-two hours after the procedure
the levels of plasma dynorphin in blood from the antecubital vein had decreased significantly
but they did not decrease to the normal range. Plasma dynorphin levels in blood from the femoral vein were positively correlated with the mean left atrial pressure and the mean right atrial pressure before the first balloon inflation. Plasma dynorphin levels in blood from the antecubital vein were positively correlated with the heart rate and the mean transmitral pressure gradient
and negatively with the mitral valve area before and 72 hours after PBMC.