FOLLOWUS
1Department of Radiology,Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
2Department of Pathology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
3Siemens Healthcare Ltd., Beijing 100102, China
*Xuan Wang, Tel: 86-10-69157438, Fax: 86-10-69155509, E-mail: dr_wangxuan@163.com;
*Zhengyu Jin, Tel: 86-10-69155441, Fax: 86-10-69155442, E-mail: jinzy@pumch.cn
收稿日期:2020-09-15,
网络出版日期:2020-12-01,
纸质出版日期:2021-06-30
Scan QR Code
徐佳, 王萱, 金征宇, 等. 探索应用延长至50分钟的钆赛酸二钠增强磁共振T1 Maps评价大鼠肝纤维化模型肝功能的价值:延长的肝胆期可能提供帮助[J]. 中国医学科学杂志(英文版), 2021,36(2):110-119.
Xu Jia, Wang Xuan, Jin Zhengyu, et al. Assessing Liver Function by T1 Maps on Gd-EOB-DTPA-Enhanced MRI for up to 50 Min in Rat Models of Liver Fibrosis: A Longer Hepatobiliary Time Period may Help[J]. Chinese medical sciences journal, 2021, 36(2): 110-119.
徐佳, 王萱, 金征宇, 等. 探索应用延长至50分钟的钆赛酸二钠增强磁共振T1 Maps评价大鼠肝纤维化模型肝功能的价值:延长的肝胆期可能提供帮助[J]. 中国医学科学杂志(英文版), 2021,36(2):110-119. DOI: 10.24920/003794.
Xu Jia, Wang Xuan, Jin Zhengyu, et al. Assessing Liver Function by T1 Maps on Gd-EOB-DTPA-Enhanced MRI for up to 50 Min in Rat Models of Liver Fibrosis: A Longer Hepatobiliary Time Period may Help[J]. Chinese medical sciences journal, 2021, 36(2): 110-119. DOI: 10.24920/003794.
目的
探索延长成像时间的钆赛酸二钠(Gd-EOB-DTPA)增强磁共振T1 mapping成像及快速动态增强扫描序列(DCE)、多期肝胆期磁共振成像对于大鼠肝纤维模型肝功能的评价是否存在潜在价值。
方法
40只雄性SD大鼠
分为采用四氯化碳溶液腹腔注射的肝功能损伤组[四氯化碳溶液分别注射4周(
n
=14)、8周(
n
=8)、12周(
n
=8)]以及对照组(
n
=10)。钆赛酸二钠磁共振增强扫描序列包括T1-mapping成像(延至注射对比剂后50分钟)、DCE、以及多期肝胆期成像。测量获得吲哚菁绿15分钟潴留率(ICG R15)。图像分析计算获得影像学参数如T1弛豫时间减低率(ΔT1)、ΔT1减半时间(T
ΔT1 1/2
)、相对强化率(RE)、RE达峰时间(T
max
)、灌注参数等。应用
Pearson
相关性分析比较影像学参数与ICG R15的关系。
结果
30、40、50分钟的ΔT1和ICG R15具有显著正相关性(
r
=0.784
0.653
0.757
P
=0.007
0.041
0.030)。T
ΔT1 1/2
与ICG R15具有显著正相关性(
r
=0.685
P
=0.029)。T
max
与ICG R15具有显著正相关性(
r
=0.532
P
=0.019)。
结论
晚期肝胆期的ΔT1及T
ΔT1 1/2
与肝功能具有中度相关性。延长成像时间的钆赛酸二钠增强磁共振T1 mapping成像及DCE、多期肝胆期磁共振成像对于大鼠肝纤维模型肝功能的评价具有一定价值。
Objectives
To investigate whether a longer time period of gadolinium ethoxybenzyl diethylenetriaminepen-taacetic acid (Gd-EOB-DTPA)-enhanced T1 mapping scanning
as well as dynamic contrast-enhanced (DCE) and multiple hepatobiliary phase magnetic resonance imaging (MRI) have the potential to provide information about liver function in rats with liver fibrosis.
Methods
Forty rats were divided into the carbon tetrachloride-induced hepatic injury groups [carbon tetrachloride for four (
n
=14)
eight (
n
=8)
or twelve (
n
=8) weeks] and the control group (
n
=10). Gd-EOB-DTPA-enhanced MRI was performed including T1-mapping (delayed to 50 min)
DCE
and multiple hepatobiliary phases. Indocyanine green retention rate at 15 min (ICG-R15) was determined. Parameters such as T1 reduction rate (ΔT1)
elimination half-life of ΔT1 (T
ΔT1 1/2
)
relative enhancement (RE)
time to maximum RE (T
max
)
and perfusion parameters were calculated.
Pearson
correlation analysis was used for correlation analysis between ICG-R15 and each MRI indices.
Results
ΔT1 at 30
40
and 50 min showed significant positive correlations with ICG-R15 (
r
=0.784
0.653
0.757
P
=0.007
0.041
0.030). T
ΔT1 1/2
showed a significant positive correlation with ICG-R15 (
r
=0.685
P
=0.029). T
max
showed a significant positive correlation with ICG-R15 (
r
=0.532
P
=0.019).
Conclusions
ΔT1 in the late hepatobiliary phase and T
ΔT1 1/2
exhibited moderate correlations with liver function. The longer time period of Gd-EOB-DTPA-enhanced T1 mapping scanning
as well as DCE and multiple hepatobiliary phases
may be of some value for estimating liver function in rats with liver fibrosis.
Hammond JS , Guha IN , Beckingham IJ , et al . Prediction, prevention and management of postresection liver failure . Br J Surg 2011 ; 98 ( 9 ): 1188 - 200 . doi: 10.1002/bjs.7630 1001-9294-36-2-110/bjs.7630 . DOI: 10.1002/bjs.7630 http://doi.org/10.1002/bjs.7630
Kudo M , Izumi N , Kokudo N , et al . Management of hepatocellular carcinoma in Japan: Consensus-Based Clinical Practice Guidelines proposed by the Japan Society of Hepatology (JSH) 2010 updated version . Dig Dis 2011 ; 29 ( 3 ): 339 - 64 . doi: 10.1159/000327577 1001-9294-36-2-110/000327577 . DOI: 10.1159/000327577 http://doi.org/10.1159/000327577 https://www.karger.com/Article/FullText/327577 https://www.karger.com/Article/FullText/327577
Geisel D , Ludemann L , Hamm B , et al . Imaging-based liver function tests—past, present and future . Rofo 2015 ; 187 ( 10 ): 863 - 71 . doi: 10.1055/s-0035-1553306 1001-9294-36-2-110/s-0035-1553306 . DOI: 10.1055/s-0035-1553306 http://doi.org/10.1055/s-0035-1553306
Van Beers BE , Pastor CM , Hussain HK . Primovist, eovist: what to expect? J Hepatol 2012 ; 57 ( 2 ): 421 - 9 . doi: 10.1016/j.jhep.2012.01.031 1001-9294-36-2-110/j.jhep.2012.01.031 . DOI: 10.1016/j.jhep.2012.01.031 http://doi.org/10.1016/j.jhep.2012.01.031 https://linkinghub.elsevier.com/retrieve/pii/S0168827812002486 https://linkinghub.elsevier.com/retrieve/pii/S0168827812002486
Ba-Ssalamah A , Bastati N , Wibmer A , et al . Hepatic gadoxetic acid uptake as a measure of diffuse liver disease: where are we? J Magn Reson Imaging 2017 ; 45 ( 3 ): 646 - 59 . doi: 10.1002/jmri.25518 1001-9294-36-2-110/jmri.25518 . DOI: 10.1002/jmri.25518 http://doi.org/10.1002/jmri.25518
Motosugi U , Ichikawa T , Sou H , et al . Liver parenchymal enhancement of hepatocyte-phase images in Gd-EOB-DTPA-enhanced MR imaging: which biological markers of the liver function affect the enhancement? J Magn Reson Imaging 2009 ; 30 ( 5 ): 1042 - 6 . doi: 10.1002/jmri.21956 1001-9294-36-2-110/jmri.21956 . DOI: 10.1002/jmri.21956 http://doi.org/10.1002/jmri.21956
Verloh N , Haimerl M , Zeman F , et al . Assessing liver function by liver enhancement during the hepatobiliary phase with Gd-EOB-DTPA-enhanced MRI at 3 Tesla . Eur Radiol 2014 ; 24 ( 5 ): 1013 - 9 . doi: 10.1007/s00330-014-3108-y 1001-9294-36-2-110/s00330-014-3108-y . DOI: 10.1007/s00330-014-3108-y http://doi.org/10.1007/s00330-014-3108-y
Sato Y , Matsushima S , Inaba Y , et al . Preoperative estimation of future remnant liver function following portal vein embolization using relative enhancement on gadoxetic acid disodium-enhanced magnetic resonance imaging . Korean J Radiol 2015 ; 16 ( 3 ): 523 - 30 . doi: 10.3348/kjr.2015.16.3.523 1001-9294-36-2-110/kjr.2015.16.3.523 . DOI: 10.3348/kjr.2015.16.3.523 http://doi.org/10.3348/kjr.2015.16.3.523 https://www.kjronline.org/DOIx.php?id=10.3348/kjr.2015.16.3.523 https://www.kjronline.org/DOIx.php?id=10.3348/kjr.2015.16.3.523
Ippolito D , Pecorelli A , Famularo S , et al . Assessing liver function: diagnostic efficacy of parenchymal enhancement and liver volume ratio of Gd-EOB-DTPA-enhanced MRI study during interstitial and hepatobiliary phase . Abdom Radiol (NY) 2019 ; 44 ( 4 ): 1340 - 9 . doi: 10.1007/s00261-018-1812-9 1001-9294-36-2-110/s00261-018-1812-9 . DOI: 10.1007/s00261-018-1812-9 http://doi.org/10.1007/s00261-018-1812-9
Ryeom HK , Kim SH , Kim JY , et al . Quantitative evaluation of liver function with MRI using Gd-EOB-DTPA . Korean J Radiol 2004 ; 5 ( 4 ): 231 - 9 . doi: 10.3348/kjr.2004.5.4.231 1001-9294-36-2-110/kjr.2004.5.4.231 . DOI: 10.3348/kjr.2004.5.4.231 http://doi.org/10.3348/kjr.2004.5.4.231 https://www.kjronline.org/DOIx.php?id=10.3348/kjr.2004.5.4.231 https://www.kjronline.org/DOIx.php?id=10.3348/kjr.2004.5.4.231
Saito K , Ledsam J , Sourbron S , et al . Measuring hepatic functional reserve using low temporal resolution Gd-EOB-DTPA dynamic contrast-enhanced MRI: a preliminary study comparing galactosyl human serum albumin scintigraphy with indocyanine green retention . Eur Radiol 2014 ; 24 ( 1 ): 112 - 9 . doi: 10.1007/s00330-013-2983-y 1001-9294-36-2-110/s00330-013-2983-y . DOI: 10.1007/s00330-013-2983-y http://doi.org/10.1007/s00330-013-2983-y http://link.springer.com/10.1007/s00330-013-2983-y http://link.springer.com/10.1007/s00330-013-2983-y
Ning J , Yang Z , Xie S , et al . Hepatic function imaging using dynamic Gd-EOB-DTPA enhanced MRI and pharmacokinetic modeling . Magn Reson Med 2017 ; 78 ( 4 ): 1488 - 95 . doi: 10.1002/mrm.26520 1001-9294-36-2-110/mrm.26520 . DOI: 10.1002/mrm.26520 http://doi.org/10.1002/mrm.26520
Sourbron S , Sommer WH , Reiser MF , et al . Combined quantification of liver perfusion and function with dynamic gadoxetic acid-enhanced MR imaging . Radiology 2012 ; 263 ( 3 ): 874 - 83 . doi: 10.1148/radiol.12110337 1001-9294-36-2-110/radiol.12110337 . DOI: 10.1148/radiol.12110337 http://doi.org/10.1148/radiol.12110337
Katsube T , Okada M , Kumano S , et al . Estimation of liver function using T1 mapping on Gd-EOB-DTPA-enhanced magnetic resonance imaging . Invest Radiol 2011 ; 46 ( 4 ): 277 - 83 . doi: 10.1097/RLI.0b013e318200f67d 1001-9294-36-2-110/RLI.0b013e318200f67d . DOI: 10.1097/RLI.0b013e318200f67d http://doi.org/10.1097/RLI.0b013e318200f67d http://journals.lww.com/00004424-201104000-00009 http://journals.lww.com/00004424-201104000-00009
Haimerl M , Verloh N , Zeman F , et al . Assessment of clinical signs of liver cirrhosis using T1 mapping on Gd-EOB-DTPA-enhanced 3T MRI . PLoS One 2013 ; 8 ( 12 ): e85658 . doi: 10.1371/journal.pone.0085658 1001-9294-36-2-110/journal.pone.0085658 . DOI: 10.1371/journal.pone.0085658 http://doi.org/10.1371/journal.pone.0085658 https://dx.plos.org/10.1371/journal.pone.0085658 https://dx.plos.org/10.1371/journal.pone.0085658
Haimerl M , Verloh N , Fellner C , et al . MRI-based estimation of liver function: Gd-EOB-DTPA-enhanced T1 relaxometry of 3T vs . the MELD score . Sci Rep 2014 ; 4 : 5621 . doi: 10.1038/srep05621 1001-9294-36-2-110/srep05621 . DOI: 10.1038/srep05621 http://doi.org/10.1038/srep05621 https://doi.org/10.1038/srep05621 https://doi.org/10.1038/srep05621
Kamimura K , Fukukura Y , Yoneyama T , et al . Quantitative evaluation of liver function with T1 relaxation time index on Gd-EOB-DTPA-enhanced MRI: comparison with signal intensity-based indices . J Magn Reson Imaging 2014 ; 40 ( 4 ): 884 - 9 . doi: 10.1002/jmri.24443 1001-9294-36-2-110/jmri.24443 . DOI: 10.1002/jmri.24443 http://doi.org/10.1002/jmri.24443 http://doi.wiley.com/10.1002/jmri.v40.4 http://doi.wiley.com/10.1002/jmri.v40.4
Zhou ZP , Long LL , Qiu WJ , et al . Comparison of 10- and 20-min hepatobiliary phase images on Gd-EOB-DTPA-enhanced MRI T1 mapping for liver function assessment in clinic . Abdom Radiol (NY) 2017 ; 42 ( 9 ): 2272 - 8 . doi: 10.1007/s00261-017-1143-2 1001-9294-36-2-110/s00261-017-1143-2 . DOI: 10.1007/s00261-017-1143-2 http://doi.org/10.1007/s00261-017-1143-2
Yoon JH , Lee JM , Kim E , et al . Quantitative liver function analysis: volumetric T1 mapping with fast multisection B1 inhomogeneity correction in hepatocyte-specific contrast-enhanced liver MR imaging . Radiology 2017 ; 282 ( 2 ): 408 - 17 . doi: 10.1148/radiol.2016152800 1001-9294-36-2-110/radiol.2016152800 . DOI: 10.1148/radiol.2016152800 http://doi.org/10.1148/radiol.2016152800 http://pubs.rsna.org/doi/10.1148/radiol.2016152800 http://pubs.rsna.org/doi/10.1148/radiol.2016152800
Nakagawa M , Namimoto T , Shimizu K , et al . Measuring hepatic functional reserve using T1 mapping of Gd-EOB-DTPA enhanced 3T MR imaging: a preliminary study comparing with 99mTc GSA scintigraphy and signal intensity based parameters . Eur J Radiol 2017 ; 92 : 116 - 23 . doi: 10.1016/j.ejrad.2017.05.011 1001-9294-36-2-110/j.ejrad.2017.05.011 . DOI: 10.1016/j.ejrad.2017.05.011 http://doi.org/10.1016/j.ejrad.2017.05.011 https://linkinghub.elsevier.com/retrieve/pii/S0720048X17301900 https://linkinghub.elsevier.com/retrieve/pii/S0720048X17301900
Ding Y , Rao SX , Chen C , et al . Assessing liver function in patients with HBV-related HCC: a comparison of T(1) mapping on Gd-EOB-DTPA-enhanced MR imaging with DWI . Eur Radiol 2015 ; 25 ( 5 ): 1392 - 8 . doi: 10.1007/s00330-014-3542-x 1001-9294-36-2-110/s00330-014-3542-x . DOI: 10.1007/s00330-014-3542-x http://doi.org/10.1007/s00330-014-3542-x http://link.springer.com/10.1007/s00330-014-3542-x http://link.springer.com/10.1007/s00330-014-3542-x
Yuan J , Chow SK , Yeung DK , et al . Quantitative evaluation of dual-flip-angle T1 mapping on DCE-MRI kinetic parameter estimation in head and neck . Quant Imaging Med Surg 2012 ; 2 ( 4 ): 245 - 53 . doi: 10.3978/j.issn.2223-4292.2012.11.04 1001-9294-36-2-110/j.issn.2223-4292.2012.11.04 . DOI: 10.3978/j.issn.2223-4292.2012.11.04 http://doi.org/10.3978/j.issn.2223-4292.2012.11.04
Kim KA , Herigault G , Kim MJ , et al . Three-dimensional contrast-enhanced hepatic MR imaging: comparison between a centric technique and a linear approach with partial Fourier along both slice and phase directions . J Magn Reson Imaging 2011 ; 33 ( 1 ): 160 - 6 . doi: 10.1002/jmri.22436 1001-9294-36-2-110/jmri.22436 . DOI: 10.1002/jmri.22436 http://doi.org/10.1002/jmri.22436 http://doi.wiley.com/10.1002/jmri.v33.1 http://doi.wiley.com/10.1002/jmri.v33.1
Sheng RF , Wang HQ , Yang L , et al . Assessment of liver fibrosis using T1 mapping on Gd-EOB-DTPA-enhanced magnetic resonance . Dig Liver Dis 2017 ; 49 ( 7 ): 789 - 95 . doi: 10.1016/j.dld.2017.02.006 1001-9294-36-2-110/j.dld.2017.02.006 . DOI: 10.1016/j.dld.2017.02.006 http://doi.org/10.1016/j.dld.2017.02.006 https://linkinghub.elsevier.com/retrieve/pii/S1590865817302074 https://linkinghub.elsevier.com/retrieve/pii/S1590865817302074
Kundel HL , Polansky M . Measurement of observer agreement . Radiology 2003 ; 228 ( 2 ): 303 - 8 . doi: 10.1148/radiol.2282011860 1001-9294-36-2-110/radiol.2282011860 . DOI: 10.1148/radiol.2282011860 http://doi.org/10.1148/radiol.2282011860 http://pubs.rsna.org/doi/10.1148/radiol.2282011860 http://pubs.rsna.org/doi/10.1148/radiol.2282011860
Zhou ZP , Long LL , Huang LJ , et al . Gd-EOB-DTPA-enhanced MRI T1 mapping for assessment of liver function in rabbit fibrosis model: comparison of hepatobiliary phase images obtained at 10 and 20 min . Radiol Med 2017 ; 122 ( 4 ): 239 - 47 . doi: 10.1007/s11547-016-0719-1 1001-9294-36-2-110/s11547-016-0719-1 . DOI: 10.1007/s11547-016-0719-1 http://doi.org/10.1007/s11547-016-0719-1 http://link.springer.com/10.1007/s11547-016-0719-1 http://link.springer.com/10.1007/s11547-016-0719-1
Haimerl M , Schlabeck M , Verloh N , et al . Volume-assisted estimation of liver function based on Gd-EOB-DTPA-enhanced MR relaxometry . Eur Radiol 2016 ; 26 ( 4 ): 1125 - 33 . doi: 10.1007/s00330-015-3919-5 1001-9294-36-2-110/s00330-015-3919-5 . DOI: 10.1007/s00330-015-3919-5 http://doi.org/10.1007/s00330-015-3919-5 http://link.springer.com/10.1007/s00330-015-3919-5 http://link.springer.com/10.1007/s00330-015-3919-5
Zhou ZP , Long LL , Qiu WJ , et al . Evaluating segmental liver function using T1 mapping on Gd-EOB-DTPA-enhanced MRI with a 3.0 Tesla . BMC Med Imaging 2017 ; 17 ( 1 ): 20 . doi: 10.1186/s12880-017-0192-x 1001-9294-36-2-110/s12880-017-0192-x . DOI: 10.1186/s12880-017-0192-x http://doi.org/10.1186/s12880-017-0192-x http://bmcmedimaging.biomedcentral.com/articles/10.1186/s12880-017-0192-x http://bmcmedimaging.biomedcentral.com/articles/10.1186/s12880-017-0192-x
Unal E , Idilman IS , Karcaaltincaba M . Multiparametric or practical quantitative liver MRI: towards millisecond, fat fraction, kilopascal and function era . Expert Rev Gastroenterol Hepatol 2017 ; 11 ( 2 ): 167 - 82 . doi: 10.1080/17474124.2017.1271710 1001-9294-36-2-110/17474124.2017.1271710 . DOI: 10.1080/17474124.2017.1271710 http://doi.org/10.1080/17474124.2017.1271710 https://www.tandfonline.com/doi/full/10.1080/17474124.2017.1271710 https://www.tandfonline.com/doi/full/10.1080/17474124.2017.1271710
Yoneyama T , Fukukura Y , Kamimura K , et al . Efficacy of liver parenchymal enhancement and liver volume to standard liver volume ratio on Gd-EOB-DTPA-enhanced MRI for estimation of liver function . Eur Radiol 2014 ; 24 ( 4 ): 857 - 65 . doi: 10.1007/s00330-013-3086-5 1001-9294-36-2-110/s00330-013-3086-5 . DOI: 10.1007/s00330-013-3086-5 http://doi.org/10.1007/s00330-013-3086-5 http://link.springer.com/10.1007/s00330-013-3086-5 http://link.springer.com/10.1007/s00330-013-3086-5
Tsuda N , Matsui O . Signal profile on Gd-EOB-DTPA-enhanced MR imaging in non-alcoholic steatohepatitis and liver cirrhosis induced in rats: correlation with transporter expression . Eur Radiol 2011 ; 21 ( 12 ): 2542 - 50 . doi: 10.1007/s00330-011-2228-x 1001-9294-36-2-110/s00330-011-2228-x . DOI: 10.1007/s00330-011-2228-x http://doi.org/10.1007/s00330-011-2228-x http://link.springer.com/10.1007/s00330-011-2228-x http://link.springer.com/10.1007/s00330-011-2228-x
Saito S , Obata A , Kashiwagi Y , et al . Dynamic contrast-enhanced MRI of the liver in Mrp2-deficient rats using the hepatobiliary contrast agent Gd-EOB-DTPA . Invest Radiol 2013 ; 48 ( 7 ): 548 - 53 . doi: 10.1097/RLI.0b013e3182856a06 1001-9294-36-2-110/RLI.0b013e3182856a06 . DOI: 10.1097/RLI.0b013e3182856a06 http://doi.org/10.1097/RLI.0b013e3182856a06 http://journals.lww.com/00004424-201307000-00007 http://journals.lww.com/00004424-201307000-00007
Hinrichs H , Hinrichs JB , Gutberlet M , et al . Functional gadoxetate disodium-enhanced MRI in patients with primary sclerosing cholangitis (PSC) . Eur Radiol 2016 ; 26 ( 4 ): 1116 - 24 . doi: 10.1007/s00330-015-3913-y 1001-9294-36-2-110/s00330-015-3913-y . DOI: 10.1007/s00330-015-3913-y http://doi.org/10.1007/s00330-015-3913-y
Yamada T , Kashiwagi Y , Rokugawa T , et al . Evaluation of hepatic function using dynamic contrast-enhanced magnetic resonance imaging in melanocortin 4 receptor-deficient mice as a model of nonalcoholic steatohepatitis . Magn Reson Imaging 2019 ; 57 : 210 - 7 . doi: 10.1016/j.mri.2018.11.013 1001-9294-36-2-110/j.mri.2018.11.013 . DOI: 10.1016/j.mri.2018.11.013 http://doi.org/10.1016/j.mri.2018.11.013 https://linkinghub.elsevier.com/retrieve/pii/S0730725X18302510 https://linkinghub.elsevier.com/retrieve/pii/S0730725X18302510
Zhang W , Kong X , Wang ZJ , et al . Dynamic contrast-enhanced magnetic resonance imaging with Gd-EOB-DTPA for the evaluation of liver fibrosis induced by carbon tetrachloride in rats . PLoS One 2015 ; 10 ( 6 ): e0129621 . doi: 10.1371/journal.pone.0129621 1001-9294-36-2-110/journal.pone.0129621 . DOI: 10.1371/journal.pone.0129621 http://doi.org/10.1371/journal.pone.0129621 https://dx.plos.org/10.1371/journal.pone.0129621 https://dx.plos.org/10.1371/journal.pone.0129621
Yang JF , Zhao ZH , Zhang Y , et al . Dual-input two-compartment pharmacokinetic model of dynamic contrast-enhanced magnetic resonance imaging in hepatocellular carcinoma . World J Gastroenterol 2016 ; 22 ( 13 ): 3652 - 62 . doi: 10.3748/wjg.v22.i13.3652 1001-9294-36-2-110/wjg.v22.i13.3652 . DOI: 10.3748/wjg.v22.i13.3652 http://doi.org/10.3748/wjg.v22.i13.3652 http://www.wjgnet.com/1007-9327/full/v22/i13/3652.htm http://www.wjgnet.com/1007-9327/full/v22/i13/3652.htm
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621