FOLLOWUS
1. 1Department of Radiology, Hainan Branch of Chinese PLA General Hospital, Sanya 572013, China
2. 2Department of Radiology, Chinese PLA General Hospital, Beijing 100853, China
*Corresponding author Tel: 86-10-66939592, E-mail: cjr.malin@vip.163.com
收稿日期:2016-10-05,
网络出版日期:2017-12-30,
纸质出版日期:2017-12
Scan QR Code
陈志晔, 刘梦琦, 马林. 基于表面的形态测量学:3T与7T高分辨磁共振结构成像受试者内比较[J]. 中国医学科学杂志(英文版), 2017,32(4):226-231.
Chen Zhiye, Liu Mengqi, Ma Lin. Surface-Based Morphometry of Human Brain: Intra-Individual Comparison Between 3T and 7T High Resolution Structural MR Imaging△[J]. Chinese medical sciences journal, 2017, 32(4): 226-231.
陈志晔, 刘梦琦, 马林. 基于表面的形态测量学:3T与7T高分辨磁共振结构成像受试者内比较[J]. 中国医学科学杂志(英文版), 2017,32(4):226-231. DOI: 10.24920/J1001-9294.2017.031.
Chen Zhiye, Liu Mengqi, Ma Lin. Surface-Based Morphometry of Human Brain: Intra-Individual Comparison Between 3T and 7T High Resolution Structural MR Imaging△[J]. Chinese medical sciences journal, 2017, 32(4): 226-231. DOI: 10.24920/J1001-9294.2017.031.
目的
2
高分辨磁共振结构成像可以揭示大脑皮层的结构特征
并可以解释正常脑发育及神经心理性疾病。本研究旨在采用基于表面的形态测量学方法比较正常受试者在3T与7T磁共振高分辨结构成像的差异。
方法
2
12个健康志愿者分别在3T磁共振上行三维快速T1加权快速毁损梯度回波成像及在7T磁共振上行三维T1加权磁化准备快速梯度回波序列。采用FreeSurfer软件处理数据。计算皮层厚度、白质及灰质表面积、凸率、曲率
并采用配对
t
检验进行比较。
结果
2
3T磁共振上受试者平均皮层厚度、白质总面积、灰质总面积要大于7T (左侧大脑半球P值分别是0.000
0.006及0.020;右侧大脑半球P值分别为0.000
0.000
0.000)。与3T磁共振成像比较
全脑基于表面的形态测量学证实
皮层厚度、白质表面、灰质表面、凸率、曲率在7T磁共振成象上存在减少或增加的情况。
结论
2
本研究结果证实3T与7T磁共振成像设备存在脑结构属性特征的不一致性。当采用超高场MR系统探索脑结构变化时
研究者对数据的解释应当保持谨慎态度。
Objective
2
High resolution structural MR imaging can reveal structural characteristics of cerebral cortex and provide an insight into normal brain development and neuropsychological diseases. The aim of this study was to compare cortical structural characteristics of normal human brain between 3T and 7T MRI systems using surface-based morphometry based on high resolution structural MR imaging.
Methods
2
Twelve healthy volunteers were scanned by both 3T with 3D T1-weighted fast spoiled gradient recalled echo (3D T1-FSPGR) sequence and 7T with 3D T1-weighted magnetization-prepared rapid gradient echo (3D T1-MPRAGE) sequence. MRI data were processed with FreeSurfer. The cortical thickness
white and gray matter surface area
convexity
and curvature from data of 3T and 7T were measured and compared by paired
t
-test.
Results
2
Measurements of mean cortical thickness
total white matter surface area and gray matter surface area of 3T were larger than those of 7T (left hemisphere:
P
=0.000
0.006
0.020 respectively; right hemisphere:
P
=0.000
0.000
0.000 respectively). Surface-based morphometry over the whole brain demonstrated both reduced and increased measurements of cortical thickness
white and gray surface area
convexity
and curvature at 7T compared to 3T.
Conclusions
2
Inconsistency of brain structural attribute between 3T and 7T was confirmed
and researchers should be cautious about data when using ultrahigh field MR system to investigate brain structural changes.
Fischl B , Dale AM. Measuring the thickness of the human cerebral cortex from magnetic resonance images. Proc Natl Acad Sci USA 2000 ; 97 : 11050 - 5 . doi: 10.1073/ pnas.200033797 https://doi.org/10.1073/pnas.200033797 .
Hutton C , De Vita E , Ashburner J , Deichmann R , Turner R. Voxel-based cortical thickness measurements in MRI. Neuroimage 2008 ; 40 : 1701 - 10 . doi: 10.1016/j. neuroimage.2008.01.027 https://doi.org/10.1016/j.neuroimage.2008.01.027 .
Chen Z , Li L , Sun J , Ma L. Mapping the brain in type II diabetes: Voxel-based morphometry using DARTEL. Eur J Radiol 2012 ; 81 : 1870 - 6 . doi: 10.1016/j.ejrad.2011.04.025 https://doi.org/10.1016/j.ejrad.2011.04.025 .
Mainero C , Benner T , Radding A, van der Kouwe A, Jensen R, Rosen BR, et al. In vivo imaging of cortical pathology in multiple sclerosis using ultra-high field MRI. Neurology 2009 ; 73 : 941 - 8 . doi: 10.1212/WNL.0b013e3181b64bf7 https://doi.org/10.1212/WNL.0b013e3181b64bf7 .
Bluestein KT , Pitt D , Sammet S , Zachariah CR , Nagaraj U , Knopp MV , et al. Detecting cortical lesions in multiple sclerosis at 7T using white matter signal attenuation. Magn Reson Imaging 2012 ; 30 : 907 - 15 . doi: 10.1016/j.mri.2012.03.006 https://doi.org/10.1016/j.mri.2012.03.006 .
Beisteiner R , Robinson S , Wurnig M , Hilbert M , Merksa K , Rath J , et al. Clinical fMRI: evidence for a 7T benefit over 3T. Neuroimage 2011 ; 57 : 1015 - 21 . doi: 10.1016/j.neuroimage.2011.05.010 https://doi.org/10.1016/j.neuroimage.2011.05.010 .
Lüsebrink F , Wollrab A , Speck O. Cortical thickness determination of the human brain using high resolution 3T and 7T MRI data. Neuroimage 2013 ; 70 : 122 - 31 . doi: 10.1016/j.neuroimage.2012.12.016 https://doi.org/10.1016/j.neuroimage.2012.12.016 .
Pinkhardt EH , van Elst LT , Ludolph AC , Kassubek J . Amygdala size in amyotrophic lateral sclerosis without dementia: an in vivo study using MRI volumetry. BMC Neurol 2006 ; 6 : 48 . doi: 10.1186/1471-2377-6-48 https://doi.org/10.1186/1471-2377-6-48 .
Ashburner J , Friston KJ. Voxel-based morphometry-the methods. Neuroimage 2000 ; 11 ( 6 Pt 1 ): 805 - 21 . doi: 10.1006/nimg.2000.0582 https://doi.org/10.1006/nimg.2000.0582 .
Turken AU , Herron TJ , Kang X , O'Connor LE, Sorenson DJ, Baldo JV, et al. Multimodal surface-based morphometry reveals diffuse cortical atrophy in traumatic brain injury. BMC Med Imaging 2009 ; 9 : 20 . doi: 10.1186/1471-2342-9-20 https://doi.org/10.1186/1471-2342-9-20 .
Van Essen DC , Drury HA. Structural and functional analyses of human cerebral cortex using a surface-based atlas. J Neurosci 1997 ; 17 : 7079 - 102 .
Lebedev AV , Westman E , Beyer MK , Kramberger MG , Aguilar C , Pirtosek Z , et al. Multivariate classification of patients with Alzheimer's and dementia with Lewy bodies using high-dimensional cortical thickness measurements: an MRI surface-based morphometric study. J Neurol 2013 ; 260 : 1104 - 15 . doi: 10.1007/s00415-012-6768-z https://doi.org/10.1007/s00415-012-6768-z .
Wang L , Goldstein FC , Veledar E , Levey AI , Lah JJ , Meltzer CC , et al. Alterations in cortical thickness and white matter integrity in mild cognitive impairment measured by whole-brain cortical thickness mapping and diffusion tensor imaging. AJNR Am J Neuroradiol 2009 ; 30 : 893 - 9 . doi: 10.3174/ajnr.A1484 https://doi.org/10.3174/ajnr.A1484 .
Fischl B , Sereno MI , Tootell RB , Dale AM. High-resolution intersubject averaging and a coordinate system for the cortical surface. Hum Brain Mapp 1999 ; 8 : 272 - 84 . doi: 10.1002/(SICI)1097-0193(1999)8: 4<272: AID-HBM10> 3.0.CO;2-4 https://doi.org/10.1002/(SICI)1097-0193(1999)8: 4<272: AID-HBM10> 3.0.CO;2-4 .
Fischl B , Sereno MI , Dale AM. Cortical surface-based analysis. Ⅱ: Inflation, flattening, and a surface-based coordinate system. Neuroimage 1999 ; 9 : 195 - 207 . doi: 10.1006/nimg.1998.0396 https://doi.org/10.1006/nimg.1998.0396 .
Han X , Jovicich J , Salat D, van der Kouwe A, Quinn B, Czanner S, et al. Reliability of MRI-derived measurements of human cerebral cortical thickness: the effects of field strength, scanner upgrade and manufacturer. Neuroimage 2006 ; 32 : 180 - 94 . doi: 10.1016/j.neuroimage.2006.02.051 https://doi.org/10.1016/j.neuroimage.2006.02.051 .
Dickerson BC , Fenstermacher E , Salat DH , Wolk DA , Maguire RP , Desikan R , et al. Detection of cortical thickness correlates of cognitive performance: Reliability across MRI scan sessions, scanners, and field strengths. Neuroimage 2008 ; 39 : 10 - 8 . doi: 10.1016/j.neuroimage.2007.08.042 https://doi.org/10.1016/j.neuroimage.2007.08.042 .
Gronenschild EH , Habets P , Jacobs HI , Mengelers R , Rozendaal N, van Os J, et al. The effects of FreeSurfer version, workstation type, and Macintosh operating system version on anatomical volume and cortical thickness measurements. PLoS One 2012 ; 7 : e38234 . doi: 10.1371/journal.pone.0038234 https://doi.org/10.1371/journal.pone.0038234 .
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621