Chinese Medical Sciences Journal ›› 2012, Vol. 27 ›› Issue (4): 225-231.doi: 10.1016/S1001-9294(13)60006-1
Previous Articles Next Articles
Kai Sun1*, Guo-rong Liu1, Yue-chun Li1, Rui-juan Han2, Li-fang Cui1, Li-jun Ma1, Li-gang Li3, Chang-yong Li4
Received:
2012-05-13
Published:
2013-01-07
Online:
2013-01-07
Contact:
*Corresponding author Tel: 86-13654844693, E-mail: Henrysk@163.com
E-mail:Henrysk@163.com
About author:
*Corresponding author Tel: 86-13654844693, E-mail: Henrysk@163.com
Kai Sun, Guo-rong Liu, Yue-chun Li, Rui-juan Han, Li-fang Cui, Li-jun Ma, Li-gang Li, Chang-yong Li. Intravenous Contrast Material Administration at High-pitch Dual-source CT Coronary Angiography: Bolus-tracking Technique with Shortened Time of Respiratory Instruction Versus Test Bolus Technique[J].Chinese Medical Sciences Journal, 2012, 27(4): 225-231.
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
1. | Husmann L,Herzog BA,Burger IA,et al. Usefulness of additional coronary calcium scoring in low-dose CT coronary angiography with prospective ECG-triggering impact on total effective radiation dose and diagnostic accuracy. Acad Radiol 2010; 17:201-6 |
2. | Ropers D,Pohle FK,Kuettner A,et al. Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation. Circulation 2006; 114:2334-41 |
3. | Carrascosa P,Capunay C,Deviggiano A,et al. Accuracy of low-dose prospectively gated axial coronary CT angiography for the assessment of coronary artery stenosis in patients with stable heart rate. J Cardiovasc Comput Tomogr 2010; 4:197-205 |
4. | Xu Y,Tang L,Zhu X,et al. Comparison of dual-source CT coronary angiography and conventional coronary angiography for detecting coronary artery disease. Int J Cardiovasc Imaging 2010; 26 Suppl 1:75-81 |
5. | Zhang LJ,Wu SY,Wang J,et al. Diagnostic accuracy of dual-source CT coronary angiography: the effect of average heart rate,heart rate variability,and calcium score in a clinical perspective. Acta Radiol 2010; 51:727-40 |
6. | Cademartiri F,Maffei E,Palumbo AA,et al. Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography. Eur Radiol 2008; 18: 576-83 |
7. | Cademartiri F,Nieman K,der Lugt AV,et al. Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-trac- king technique. Radiology 2004; 233:817-23 |
8. | Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 2010; 256:32-61 |
9. | Kirchner J,Kickuth R,Laufer U,et al. Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients. Clin Radiol 2000; 55:368-73 |
10 | Mehnert F,Pereira PL,Trubenbach J,et al. Automatic bolus tracking in monophasic spiral CT of the liver: liver-to-lesion conspicuity. Eur Radiol 2001; 11:580-4 |
11 | Sandstede JJ,Tschammler A,Beer M,et al. Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT. Eur Radiol 2001; 11:1396-400 |
12 | Achenbach S,Goroll T,Seltmann M,et al. Detection of coronary artery stenoses by low-dose,prospectively ECG-triggered,high-pitch spiral coronary CT angiography. JACC Cardiovasc Imaging 2011; 4:328-37 |
13 | Alkadhi H,Stolzmann P,Desbiolles L,et al. Low-dose,128-slice,dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode. Heart 2010; 96:933-8 |
14 | Leschka S,Stolzmann P,Desbiolles L,et al. Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience. Eur Radiol 2009; 19:2896-903 |
15 | Achenbach S,Marwan M,Ropers D,et al. Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J 2010; 31:340-6 |
16 | Leschka S,Stolzmann P,Desbiolles L,et al. Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience. Eur Radiol 2009; 19:2896-903 |
17 | Lell M,Marwan M,Schepis T,et al. Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience. Eur Radiol 2009; 19:2576-83 |
18 | Austen WG,Edwards JE,Frye RL,et al. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease,Council on Cardiovascular Surgery,American Heart Association. Circulation 1975; 51:5-40 |
19 | Qi W,Li J,Du X. Method for automatic tube current selection for obtaining a consistent image quality and dose optimization in a cardiac multidetector CT. Korean J Radiol 2009; 10:568-74 |
20 | 20.European Study Group of Radiologist and Physicists. European Guidelines on quality criteria for computed tomography. [cited 2012 Sep 12]. Available from http:// www.drs.dk/guidelines/ct/quality/htmlindex.htm |
21 | Johnson TR,Nikolaou K,Wintersperger BJ,et al. Optimization of contrast material administration for electrocardiogram-gated computed tomographic angiography of the chest. J Comput Assist Tomogr 2007; 31:265-71 |
22 | Wang YN,Li L,Kong LY,et al. Coronary computed tomographic angiography using low-dose prospectively electrocardiographic triggered high-pitch spiral acquisition by dual-source computed tomography: image quality and radiation dose. Zhongguo Yi Xue Ke Xue Yuan Xue Bao 2010; 32:597-600 |
23 | Sommer WH,Albrecht E,Bamberg F,et al. Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT. Am J Roentgenol 2010; 195:1306-12 |
24 | Wang D,Hu XH,Zhang SZ,et al. Image quality and dose performance of 80 kV low dose scan protocol in high-pitch spiral coronary CT angiography: feasibility study. Int J Cardiovasc Imaging 2012; 28:415-23 |
25 | Achenbach S,Marwan M,Ropers D,et al. Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J 2010; 31:340-6 |
[1] | Chen Zhiye, Liu Mengqi, Yu Shengyuan, Ma Lin. Multi-parametric MRI Diagnoses Cerebellar Hemangioblastoma: A Case Report [J]. Chinese Medical Sciences Journal, 2018, 33(3): 188-193. |
[2] | Du Junhui, Li Rong. Can Fundus Fluorescein Angiography be Performed for Diabetic Patients on Oral Metformin?△ [J]. Chinese Medical Sciences Journal, 2017, 32(2): 119-122. |
[3] | Zhi-wei Wang, Hua-dan Xue, Xiao-guang Li, Jie Pan, Xiao-bo Zhang, Zheng-yu Jin. Life-threatening Spontaneous Retroperitoneal Haemorrhage: Role of Multidetector CT-angiography for the Emergency Management [J]. Chinese Medical Sciences Journal, 2016, 31(1): 43-48. |
[4] | Qi Cheng*, Sha-sha Wang, Xian-sheng Zhu, Fan Li. Evaluation of Tubal Patency with Transvaginal Three- dimensional Hysterosalpingo-contrast Sonography [J]. Chinese Medical Sciences Journal, 2015, 30(2): 70-75. |
[5] | Hao Sun, Hua-dan Xue, Zheng-yu Jin, Xuan Wang, Yu Chen, Yong-lan He, Da-ming Zhang, Liang Zhu. Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis [J]. Chinese Medical Sciences Journal, 2014, 29(4): 214-220. |
[6] | Guo-gui Sun, Wan-ning Hu, Jun Zhang, Cheng-lin Li, and Cong-rong Yang. Effect of Nitric Oxide on Esophageal Cancer Cell Line TE-1 [J]. Chinese Medical Sciences Journal, 2013, 28(1): 44-49. |
[7] | Lu Lin, Yi-ning Wang, Ling-yan Kong, Zheng-yu Jin, Guang-ming Lu, Zhao-qi Zhang, Jian Cao, Shuo Li, Lan Song, Zhi-wei Wang, Kang Zhou, Ming Wang. 128-slice Dual-source Computed Tomography Coronary Angiography in Patients with Atrial Fibrillation: Image Quality and Radiation Dose of Prospectively Electrocardiogram- triggered Sequential Scan Compared with Retrospectively Electrocardiogram-gated Spiral Scan [J]. Chinese Medical Sciences Journal, 2012, 27(4): 195-200. |
[8] | Yong-lan He, Da-ming Zhang, Hua-dan Xue*, Zheng-yu Jin. Clinical Value of Dual-energy CT in Detection of Pancreatic Adenocarcinoma: Investigation of the Best Pancreatic Tumor Contrast to Noise Ratio [J]. Chinese Medical Sciences Journal, 2012, 27(4): 207-212. |
[9] | Kai Sun, Rui-juan Han, Li-fang Cui, Rui-ping Zhao, Li-jun Ma, Li-jun Wang, Li-gang Li, Chang-yong Li. Feasibility and Diagnostic Accuracy for Assessment of Coronary Artery Stenosis of Prospectively Electrocardiogram-gated High-pitch Spiral Acquisition Mode Dual-source CT Coronary Angiography in Patients with Relatively Higher Heart Rates: in Comparison with Catheter Coronary Angiography△ [J]. Chinese Medical Sciences Journal, 2012, 27(4): 213-219. |
[10] | Ming-bo Zhang, En-ze Qu, Ji-Bin Liu, Jin-rui Wang. Quantitative Assessment of Hepatic Fibrosis by Contrast-enhanced Ultrasonography [J]. Chinese Medical Sciences Journal, 2011, 26(4): 208-215. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||
|
Supervised by National Health Commission of the People's Republic of China
9 Dongdan Santiao, Dongcheng district, Beijing, 100730 China
Tel: 86-10-65105897 Fax:86-10-65133074
E-mail: cmsj@cams.cn www.cmsj.cams.cn
Copyright © 2018 Chinese Academy of Medical Sciences
All right reserved.
京公安备110402430088 京ICP备06002729号-1